7
7.3
List of faults and warnings
7-712
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
891
PLUS software limit switch actuated coupled
Cause
With the actual master drive velocity, this coupling axis will probably
reach or pass the PLUS software limit switch.
This warning is output if the coupled axis has fallen below 200% of the
braking travel up to the PLUS software limit switch.
Remedy
Traverse the master drive so that this coupling axis goes into the per-
missible traversing range.
Acknowledgement not required
Stop response
STOP VII
892
MINUS software limit switch actuated coupled
Cause
With the actual master drive velocity, this coupling axis will probably
reach or pass the MINUS software limit switch.
This warning is output if the coupled axis has fallen below 200% of the
braking travel up to the MINUS software limit switch.
Remedy
Traverse the master drive so that this coupling axis goes into the per-
missible traversing range.
Acknowledgement not required
Stop response
STOP VII
893
Function 73 only effective at terminal I0.x
Cause
The terminal function 73 ”Coupling on I0” is only effective at terminal
I0.x.
Remedy
Assign terminal I0.x to function 73.
Acknowledgement not required
Stop response
STOP VII
894
Inputs, optional TERMINAL module assigned twice
Cause
The input terminals on the optional TERMINAL module can only be
used by one drive.
Remedy
Check and correct P0676 (A) and P0676 (B).
Acknowledgement not required
Stop response
STOP VII
895
Outputs, optional TERMINAL module assigned twice
Cause
Only one drive can use the output terminals on the optional TERMINAL
module.
Remedy
Check and correct P0696 (A) and P0696 (B).
Acknowledgement not required
Stop response
STOP VII
7 Fault Handling/Diagnostics
01.99
04.05