background image

CPX-AP-A-16DI-D-M12-5P

Digital input module

Operating instruc-

tions

8160711

2022-07

[8160713]

Summary of Contents for CPX-AP-A-16DI-D-M12-5P

Page 1: ...CPX AP A 16DI D M12 5P Digital input module Operating instruc tions 8160711 2022 07 8160713 ...

Page 2: ...Translation of the original instructions ...

Page 3: ...tended use 5 2 3 Training of qualified personnel 5 3 Additional information 5 4 Product overview 6 4 1 Structure 6 4 1 1 Product design 6 4 1 2 LED displays 7 4 1 3 Connecting elements 7 4 2 Function 7 4 2 1 Digital inputs 8 4 2 2 Channel diagnostics 8 5 Mounting 8 6 Installation 8 7 Commissioning 8 8 Parameterisation 9 9 Diagnostics and fault clearance 9 9 1 Diagnostics messages 9 9 2 LED display...

Page 4: ...input module CPX AP A 16DI D M12 from revision 1 Tab 2 Product version The product version can be determined from the product labelling There may be an updated version of this document for this or later product versions è www festo com sp 1 3 Product labelling The product labelling and the Data Matrix Code are printed on the housings of the modules Scanning the Data Matrix Code with an appropriate...

Page 5: ...llows Use only in an industrial environment Outside industrial environments e g in commercial and residential mixed use areas it may be necessary to take measures to suppress radio interference Use only in combination with modules and components that are approved for the applicable product variant è www festo com catalogue 2 3 Training of qualified personnel Work on the product may only be carried...

Page 6: ... 7 2 4 6 8 9 Fig 1 Product design 1 Connection for inputs 0 1 X0 2 Connection for inputs 2 3 X1 3 Connection for inputs 4 5 X2 4 Connection for inputs 6 7 X3 5 Connection for inputs 8 9 X4 6 Connection for inputs 10 11 X5 7 Connection for inputs 12 13 X6 8 Connection for inputs 14 15 X7 9 Inscription label optional ...

Page 7: ...ing elements Connection for inputs X0 X7 M12 socket 5 pin A coded Signal 1 24 V DC sensor supply 2 Input 1 3 5 7 9 11 13 15 3 0 V DC sensor supply 4 Input 0 2 4 6 8 10 12 14 5 Functional earth FE Tab 4 Connection for inputs Digital and analogue signal lines Max cable length 30 m Tab 5 Requirements for the connecting cable 4 2 Function The module provides 16 digital inputs ...

Page 8: ...r supply is switched on again automatically The electronic fuse of the module is a slow blow type Sensors can therefore also be connected with a higher short term current requirement 4 2 2 Channel diagnostics The channel diagnostics give an overview of any pending diagnostic messages for the channels of the selected module 5 Mounting Carry out assembly according to the Automation system CPX AP A o...

Page 9: ...s factory setting 2 10 ms 3 20 ms 1 ENUM_ID rw 20085 Measured value of temperature AP ASIC C 1 INT16 ro 20087 Current measured value of logic supply PS 1 UINT16 ro 20088 Current measured value of load supply PL 1 UINT16 ro 20093 Hardware version 1 UINT8 ro 1 ro read only rw read write Tab 7 Parameter 9 Diagnostics and fault clearance 9 1 Diagnostics messages The following table contains the diagno...

Page 10: ... AP master Check communication cable AP Diag nostic status Error 08 01 0130 134283568 AP module process data output watchdog timed out The process data watchdog for the outputs timed out in the module Remedy Restart AP master Check wiring Diag nostic status Error 08 01 0131 134283569 AP module process data input watchdog timed out The process data watchdog for the inputs timed out in the module Re...

Page 11: ...s and fault clearance 11 ID hex dec Message Description 08 01 01A2 134283682 Device in System State Emergency Operation Remedy Restart system Update firmware to latest version Contact Festo service Diag nostic status Error Tab 8 Diagnostic messages ...

Page 12: ...rity Information flashing red 0 5 Hz Module diagnostics active Degree of severity Warning e g parameterisation error Take appropriate remedial action e g check parameterisation red light Module diagnostics active Degree of severity Error e g undervoltage in logic supply PS Take appropriate remedial action e g check logic supply PS flashing red 2 Hz Module ramp up not yet completed System communica...

Page 13: ...96 Ambient temperature C 20 50 Storage temperature C 20 70 Humidity non condensing 5 95 Assigned address space inputs Byte 2 Module code hex dec 0x3001 12289d Module identification CPX AP A 16DI D M12 5P Protection against electric shock protec tion against direct and indirect contact in accordance with IEC 60204 1 and IEC 60364 4 41 By the use of SELV PELV circuits Safe extra low voltage Protecte...

Page 14: ... 2022 07 Technical data Power supply Logic supply PS V DC 24 25 Intrinsic current consump tion at nominal operating voltage 24 V from PS mA Typically 40 Diagnostics message under voltage in logic supply PS V DC 18 Tab 12 Power supply ...

Page 15: ...No Electrical isolation between inputs and PS No Sensor supply Sensor power supply SEN V DC 24 25 Voltage drop at short circuit protection reduction SEN V DC 1 Reverse polarity protection 24 V SEN against 0 V SEN Yes Potential difference between 0 V SEN external and 0 V SEN internal Not permissible Sensor power supply short circuit protection Short circuit protection Electronic Trigger level A 0 5...

Page 16: ... 2022 all rights reserved to Festo SE Co KG Copyright Festo SE Co KG 73734 Esslingen Ruiter Straße 82 Deutschland Phone 49 711 347 0 Internet www festo com ...

Reviews: