Image, input signals, Part 1
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned32
RO
... is an image of selected input signals (terminal and PROFIBUS signals).
Bit 0
ON/OFF 1
Bit 1
Operating condition/OFF 2
Bit 2
Operating condition/OFF 3
Bit 3
Enable inverter/pulse inhibit
Bit 4
Ramp-function generator enable <––> operating condition/reject traversing task
Bit 5
Start ramp-function generator/stop <––> operating condition/intermediate stop
Bit 6
Enable setpoint <––> activate traversing task (edge)
Bit 7
Reset fault memory
Bit 8
Jog 1 ON/OFF
Bit 9
Jog 2 ON/OFF
Bit 10 Control requested/no control requested
Bit 11 Start referencing/cancel referencing
Bit 12 Open holding braking as test/do no open
Bit 13 Ramp-up time zero for controller enable <––> external block change
Bit 14 Torque-controlled operation
Bit 15 Spindle positioning on <––> request passive referencing
Bit 16 Signal status, terminal 65.x
Bit 17 Supply infeed module, signal status terminal 64
Bit 18 Signal status terminal 663
Bit 19 Line supply infeed module signal status terminal 63/terminal 48
Bit 21 Equivalent zero mark
Bit 22 Flying measurement/length measurement