5
5.6
Net data (PKW and PZD area)
5-253
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Error code
Table 5-24
Fault code in Gx_XIST2
Gx_XIST2
Meaning
Possible causes/description
1
hex
Encoder sum error
The fault description should be taken from the following faults (refer
to Chapter 7.3.2):
Fault 514
Motor measuring system (encoder 1)
Fault 609
Encoder limiting frequency exceeded
Fault 512
Direct measuring system (encoder 2)
Fault 615
DM encoder limiting frequency exceeded
2
hex
Zero mark monitoring
The fault description should be taken from the following faults (refer
to Chapter 7.3.2):
Fault 508
Motor measuring system (encoder 1)
Fault 514
Direct measuring system (encoder 2)
3
hex
Abort parking encoder The ”parking axis” was already selected.
4
hex
Abort, reference mark
search
A fault is present (Gx_ZSW.15 = 1)
Parking encoder/axis active
”Flying measurement” function already active
Change of function type
No reference marker programmed
Hardware already busy with another function
Only BERO: BERO not at terminal I0.x
Not BERO: EnDat encoder used
Invalid combination of reference markers for distance–coded
encoder (1–2, 3–4, 1–2–3–4 are supported)
5
hex
Retrieve reference
value interrupted
A fault is present (Gx_ZSW.15 = 1)
Parking encoder/axis active
No reference marker programmed
Requested value not available
Change of function type
6
hex
Abort, flying measure-
ment
A fault is present (Gx_ZSW.15 = 1)
Parking encoder/axis active
Change of function type
Reference point approach still active
Measuring probe not at terminal I0.x and measuring probe 1 not
used
Hardware already busy with another function
Spindle positioning active (P0125=1, from SW 5.1)
7
hex
Abort, retrieve mea-
sured value
A fault is present (Gx_ZSW.15 = 1)
Parking encoder/axis active
Change of function type
Requested value not available
Not exactly 1 value to be retrieved
8
hex
Abort absolute value
transmission on
EnDat encoder not used
5 Communications via PROFIBUS DP
08.99
05.00
08.02