TSE & PSE 

Installation Manual

Navitas Technologies Ltd. 
C-855 Trillium Dr. 
Kitchener, Ontario N2R 1J9 
Canada 
Phone: (519) 725-7871 
Fax: (519) 725-1645 
www.navitastechnologies.com 

Summary of Contents for TSE Series

Page 1: ...TSE PSE Installation Manual Navitas Technologies Ltd C 855 Trillium Dr Kitchener Ontario N2R 1J9 Canada Phone 519 725 7871 Fax 519 725 1645 www navitastechnologies com...

Page 2: ......

Page 3: ...though the traction controller TSE and the hydraulic controller PSE can be used separately maximum efficiency will be achieved by using them as a pair THE RIGHT CONTROLLER FOR THE JOB As a rule trucks...

Page 4: ...eakening D contactor negative output When using a PC pump controller with the SE the Brown output can be used as a Line Contactor driver If you would like to do this you must contact Navitas for addit...

Page 5: ...directional contactors must be fitted with suppressors CABLE CONNECTIONS A large external plugging diode must be installed in the left motor circuit Diagram 2 This diode can usually be re used from y...

Page 6: ...double faced tape and wire exactly as shown in Wiring Diagram 3 Limit 1 and Limit 2 on the TTR are wired to the limit switch inputs B4 wh brn and B3 wh org on the TSE1000 Program the TSE1000 with the...

Page 7: ...ill reverse the direction of rotation You are now ready to set up your controller with the ProBit Please note that unlike in the case of the traction controller the limit switches are prioritized from...

Page 8: ...monitor or run diagnostics on your system D INSTALL To install new components or re install existing ones The most complete information and guide to the ProBit is available in the form of a Windows H...

Page 9: ...___________________________ __________________________________________________________________________________________ _________________________________________________________________________________...

Page 10: ...se to suit the operation max of 800 amps Peak Current limit manufacturer limit x 2 max of 900 amps Average Current limit manufacturer limit less 25 Peak Current limit Pump PC only to suit the operatio...

Page 11: ...TSE PSE Installation Manual Navitas Technologies Ltd Last Updated 6 13 2006 Page 9...

Page 12: ...TSE PSE Installation Manual Navitas Technologies Ltd Last Updated 6 13 2006 Page 10...

Page 13: ...TSE PSE Installation Manual Navitas Technologies Ltd Last Updated 6 13 2006 Page 11...

Page 14: ...PSE Installation Manual CAUTION It is very important that suppressors and blocking diodes be used on all directional contactors as indicated above Navitas Technologies Ltd Last Updated 6 13 2006 Page...