Control connections for the PC+: 
 
 

  White/yellow 

  SRO 

seat 

switch 

 

  White/green 

  accelerator 

sweep 

input 

 

  White/blue 

  accelerator 

negative 

input 

 

  White/grey 

  battery 

negative 

or 

third 

party 

BDI 

 

  White/red   bi-directional 

function 

#1 

(reach) 

 

  White/brown 

  bi-directional 

function 

#2 

(tilt) 

 

  White/orange 

  bi-directional 

function 

#3 

(aux.) 

 

  White/purple 

  optional 

on-demand 

steering 

input 

 
The five output wires (solid colors) can be connected to any solenoids as their functions will be mapped with the 
ProBit later. 
 
Cable connections are identical to the standard PC installation. 
 
To setup the system, first proceed to the normal set-up of the TSE and PSE with the ProBit. See the ProBit 
section of this manual. Then go into the <SETUP><CONTACTORS><PC+ COILS> to adjust voltage and map 
functions for the outputs of the PSE-P.  
 
 

#6- THE NAVITAS PROBIT 

 
The Navitas Technologies ProBit is a combination Installation and Customizing tool as well as a very efficient 
diagnostics and trouble-shooting aid. It consists of simple pull-down menus arranged in four main groups: 
 
 

 

A: MAINTENANCE 

 

To look at the condition of your equipment 

 

 

B: CUSTOMIZE  

To adjust your personal parameters and settings 

 

 

C: TROUBLESHOOT 

To test, monitor or run diagnostics on your system 

 

 

D: INSTALL 

 

 

To install new components, or re-install existing ones 

 
The most complete information and guide to the ProBit is available in the form of a Windows Help File from 
your Dealer or in the download area of our Website at 

http://www.navitastechnologies.com

 

This Help file is named “ProBit Faults & Settings Guide” and includes all of the faults that can be detected by 
the ProBit with an explanation of the problem and the most probable solutions. It also includes all of the 
possible settings of the parameters, the path to find the right menu, the factory defaults and some warnings 
about some of the most sensitive settings. The latest file covers ProBit version 1.41 and will be updated as new 
versions become available. 
 
The ProBit itself can also be updated if required. Contact your Dealer or Navitas Technologies for more 
information if your ProBit complains that it does not recognize a new version of controller. 
 

N/B:

  When using the ProBit with a Pump Controller (PSE550/800/1000) that is not connected to a Traction 

Controller (TSE550/600/1000) you must hold down the “A” and “B” buttons on the ProBit simultaneously prior 
to turning on the ignition key, and hold them until a small “M” appears in the corner of the screen.  

 

From that point the ProBit can be used normally to adjust the PC controller. 

Navitas Technologies Ltd. 

Last Updated: 6/13/2006 

Page 6

 

Summary of Contents for TSE Series

Page 1: ...TSE PSE Installation Manual Navitas Technologies Ltd C 855 Trillium Dr Kitchener Ontario N2R 1J9 Canada Phone 519 725 7871 Fax 519 725 1645 www navitastechnologies com...

Page 2: ......

Page 3: ...though the traction controller TSE and the hydraulic controller PSE can be used separately maximum efficiency will be achieved by using them as a pair THE RIGHT CONTROLLER FOR THE JOB As a rule trucks...

Page 4: ...eakening D contactor negative output When using a PC pump controller with the SE the Brown output can be used as a Line Contactor driver If you would like to do this you must contact Navitas for addit...

Page 5: ...directional contactors must be fitted with suppressors CABLE CONNECTIONS A large external plugging diode must be installed in the left motor circuit Diagram 2 This diode can usually be re used from y...

Page 6: ...double faced tape and wire exactly as shown in Wiring Diagram 3 Limit 1 and Limit 2 on the TTR are wired to the limit switch inputs B4 wh brn and B3 wh org on the TSE1000 Program the TSE1000 with the...

Page 7: ...ill reverse the direction of rotation You are now ready to set up your controller with the ProBit Please note that unlike in the case of the traction controller the limit switches are prioritized from...

Page 8: ...monitor or run diagnostics on your system D INSTALL To install new components or re install existing ones The most complete information and guide to the ProBit is available in the form of a Windows H...

Page 9: ...___________________________ __________________________________________________________________________________________ _________________________________________________________________________________...

Page 10: ...se to suit the operation max of 800 amps Peak Current limit manufacturer limit x 2 max of 900 amps Average Current limit manufacturer limit less 25 Peak Current limit Pump PC only to suit the operatio...

Page 11: ...TSE PSE Installation Manual Navitas Technologies Ltd Last Updated 6 13 2006 Page 9...

Page 12: ...TSE PSE Installation Manual Navitas Technologies Ltd Last Updated 6 13 2006 Page 10...

Page 13: ...TSE PSE Installation Manual Navitas Technologies Ltd Last Updated 6 13 2006 Page 11...

Page 14: ...PSE Installation Manual CAUTION It is very important that suppressors and blocking diodes be used on all directional contactors as indicated above Navitas Technologies Ltd Last Updated 6 13 2006 Page...

Reviews: