Encoder 1 fine resolution, absolute track G1_XIST2
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
9
11
–
Unsigned16
PO
... defines how many fine resolution bits are transferred for the PROFIBUS encoder interface.
This parameter applies for the fine resolution of process data G1_XIST2 when reading the ab-
solute value.
Note:
The parameter is only valid for the absolute track of the absolute value encoder.
The fine resolution for the value display for reference mark or flying measurement is defined in
P1042.
1044
Encoder 2 fine resolution G2_XIST1
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
11
11
–
Unsigned16
PO
... defines how many fine resolution bits are transferred for the PROFIBUS encoder interface.
This parameter applies for the following:
– Fine resolution for process data G2_XIST1
– Fine resolution for G2_XIST2 for reference mark or flying measurement
1045
Encoder 2 fine resolution, absolute track G2_XIST2
(–> 3.3)
Min
Standard
Max
Unit
Data type
Effective
0
9
11
–
Unsigned16
PO
... defines how many fine resolution bits are transferred for the PROFIBUS encoder interface.
This parameter applies for the fine resolution of process data G2_XIST2 when reading the ab-
solute value.
Note:
The parameter is only valid for the absolute track of the absolute value encoder.
The fine resolution for the value display for reference mark or flying measurement is defined in
P1044.
1050
IM reference mark clearance for distance-coded scales (–> 4.1)
Min
Standard
Max
Unit
Data type
Effective
0
20000
4294967295
µ
m
Unsigned32
PO
...specifies the basic clearance between two fixed reference marks. If the closed-loop identifies
that the distance between each second reference mark is different and is therefore incorrect,
the axis remains stationary. Fault 508 (zero mark monitoring, motor measuring system) is sig-
naled.
Note:
IM ––> Indirect measuring system (motor encoder)
This monitoring is only activated if P1050/P1024*1000 can either be divided by 16 or by 10.