A
A.3
List of motors
A-864
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table A-3
Parameters for unlisted motors (SRM)
Parameters
No.
Name
Units
Value
1102
Motor code number
–
1999
1103
Rated motor current
A(rms)
1104
Maximum motor current
A(rms)
1112
Motor pole pair number
–
1113
Torque constant
Nm/A
1114
Voltage constant
V(rms)
1115
Armature resistance
Ω
1116
Armature inductance
mH
1117
Motor moment of inertia
kgm
2
1118
Motor standstill current
A(rms)
1122
Motor limiting current
A(rms)
1128
Optimum load angle
Degr.
1136
No–load motor current (this is only rele-
vant for SRM with field weakening)
A(rms)
1142
Speed at the start of field weakening (is
only relevant for SRM with field weaken-
ing)
RPM
1145
Stall torque reduction factor (is only rele-
vant for SRM with field weakening)
%
1146
Maximum motor speed
RPM
1149
Reluctance torque constant
mH
1180
Lower current limit, current controller
adaptation
%
1181
Upper current limit, current controller
adaptation
%
1182
Factor, current controller adaptation
%
1400
Rated motor speed
RPM
Parameters for
unlisted motors
(SRM)
A Lists
01.99