A
A.1
Parameter list
A-800
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1013
Enable motor changeover (ARM)
(–> 2.4)
Min
Standard
Max
Unit
Data type
Effective
0
0
3
–
Unsigned16
PO
(ARM)
... the motor changeover is enabled or the motor changeover type is set.
0
Motor changeover inhibited
1
Motor changeover with pulse suppression
2
Motor changeover without pulse suppression (data set changeover)
3
Motor changeover with speed thresholds (P1247, P1248)
Note:
It is only possible to enable motor changeover in the ”Speed/torque setpoint” mode (P0700 = 1)
(refer to the index entry ”Motor changeover”).
1014
Activate V/f operation
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Unsigned16
PO
... the V/f operation is activated/de-activated for this drive.
1
V/f operation is activated
0
V/f operation is de-activated
Note: refer to the index entry ”V/f operation”
1015
Activate PE-MSD (SRM)
Min
Standard
Max
Unit
Data type
Effective
0
0
1
–
Unsigned16
PO
(SRM)
... the permanently excited spindle (PE spindle, 1FE1 motor) is activated/de-activated for this
drive.
1
Permanently excited spindle is activated
0
PE spindle is de-activated
Note: refer to the index entry ”Permanently excited spindle”
1016
Commutation angle offset (SRM SLM)
Min
Standard
Max
Unit
Data type
Effective
–360.0
0.0
360.0
Degree
Floating Point
PO
(SRM SLM)
... provides information about the rotor position.
To electrically commutate a synchronous motor, the closed-loop drive control must have data
regarding the absolute rotor position (position of the magnets with respect to the stator or sec-
ondary part). This data (commutation angle) is determined at synchronization.
Incremental measuring system:
... specifies the offset for a zero mark.
Note:
If the zero mark to the rotor position was already adjusted in the factory, a 0 is located in
P1016.
Absolute measuring system (EnDat encoder):
... specifies the angular offset to the position actual value of the EnDat encoder.
Note:
The angular offset is read out each time the drive runs up.
A Lists
01.99
! 611ue diff !
04.05