Technical Information

Joysticks

JS120 Single Axis Fingertip Joystick

powersolutions.danfoss.com

Summary of Contents for JS120

Page 1: ...Technical Information Joysticks JS120 Single Axis Fingertip Joystick powersolutions danfoss com...

Page 2: ...Converted to Danfoss layout 0301 July 2009 Corrected connector pin assignments and added output voltage curve DA February 2007 Lever length options connector pin assignments CA May 2006 Model code num...

Page 3: ...ector pin assignments 8 Mating connector details 8 Machine wiring guidelines 9 Joystick safety 9 Joystick dust and water protection 9 Joystick safety critical functions 10 Product specifications Elect...

Page 4: ...hich the handle is moved The output is configured to provide signals for fault detection circuits and a center tap provides an accurate voltage reference for the lever in its released position or a ze...

Page 5: ...ange 5 k spring return to center 0003 Short lever 25 to 75 Vs output range 5 k spring return to center 0005 Long lever 10 to 90 Vs output range 5 k spring return to center 0006 Long lever 25 to 75 Vs...

Page 6: ...d The degree to which the output is reduced can be chosen from the Code B table in Model code summary on page 5 Position switches Position switches are a standard JS120 feature The normally open switc...

Page 7: ...7 Short lever JS120 is designed to be fitted down into the panel through the panel cutout Panel seal integrity can be achieved by using sealing gasket Mounting screws can be driven to a recommended t...

Page 8: ...Not used D supply ground supply ground C Output voltage Output voltage B supply power supply power A Center tap Not used Marker on underside of mating connector indicates pin G Mating connector detail...

Page 9: ...ut one turn every 10 cm 4 in Use wire harness anchors that will allow wires to float with respect to the machine rather than rigid anchors C Caution Unused pins on mating connectors may cause intermit...

Page 10: ...ary switch Disable all joystick functions that the joystick controls when this switch is released Ensure the control system looks for the appropriate system enable switch input before the joystick is...

Page 11: ...of center 1 tolerance Insulation resistance 50 M at 500 Vdc Load resistance minimum 10 k Load current maximum 2 mA resistive Output voltage curve 90 50 10 Y Y kwa1390403298242 Mechanical characterist...

Page 12: ...o 70 C 13 F to 158 F Storage temperature 40 C to 85 C 40 F to 185 F Environmental sealing above the flange IP 66 above panel IP 40 below panel Technical Information JS120 Single Axis Fingertip Joystic...

Page 13: ...Technical Information JS120 Single Axis Fingertip Joystick Danfoss December 2016 520L0877 BC00000075en US0303 13...

Page 14: ...Technical Information JS120 Single Axis Fingertip Joystick 14 Danfoss December 2016 520L0877 BC00000075en US0303...

Page 15: ...Technical Information JS120 Single Axis Fingertip Joystick Danfoss December 2016 520L0877 BC00000075en US0303 15...

Page 16: ...6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No...