Machine wiring guidelines

Protect wires from mechanical abuse, run wires in flexible metal or plastic conduits.

Use 85˚ C (185˚ F) wire with abrasion resistant insulation and 105˚ C (221˚ F) wire should be
considered near hot surfaces.

Use a wire size that is appropriate for the module connector.

Separate high current wires such as solenoids, lights, alternators or fuel pumps from sensor and other
noise-sensitive input wires.

Run wires along the inside of, or close to, metal machine surfaces where possible, this simulates a
shield which will minimize the effects of EMI/RFI radiation.

Do not run wires near sharp metal corners, consider running wires through a grommet when
rounding a corner.

Do not run wires near hot machine members.

Provide strain relief for all wires.

Avoid running wires near moving or vibrating components.

Avoid long, unsupported wire spans.

Ground electronic modules to a dedicated conductor of sufficient size that is connected to the
battery (-).

Power the sensors and valve drive circuits by their dedicated wired power sources and ground
returns.

Twist sensor lines about one turn every 10 cm (4 in).

Use wire harness anchors that will allow wires to float with respect to the machine rather than rigid
anchors.

C

Caution

Unused pins on mating connectors may cause intermittent product performance or premature failure.
Plug all pins on mating connectors.

W

Warning

Unintended movement of the machine or mechanism may cause injury to the technician or bystanders.
Improperly protected power input lines against over current conditions may cause damage to the
hardware. Properly protect all power input lines against over-current conditions.

Joystick safety

Joystick dust and water protection

The joystick is sealed above the mounting surface to prevent dust and water ingress and is supplied with
a sealing gasket for mounting above the panel. The effectiveness of the seal is dependent on the
mounting surface being sufficiently rigid to compress the sealing gasket. The finish of the mounting
surface is critical to achieving an adequate seal and rough surface finishes, paint chips, deep scratches,
etc. should be avoided.
The joystick base below the mounting surface should be protected from dust and direct water spray.

Technical Information

JS120 Single Axis Fingertip Joystick

Product installation

 

©

 Danfoss | December 2016

520L0877 | BC00000075en-US0303 | 9

Summary of Contents for JS120

Page 1: ...Technical Information Joysticks JS120 Single Axis Fingertip Joystick powersolutions danfoss com...

Page 2: ...Converted to Danfoss layout 0301 July 2009 Corrected connector pin assignments and added output voltage curve DA February 2007 Lever length options connector pin assignments CA May 2006 Model code num...

Page 3: ...ector pin assignments 8 Mating connector details 8 Machine wiring guidelines 9 Joystick safety 9 Joystick dust and water protection 9 Joystick safety critical functions 10 Product specifications Elect...

Page 4: ...hich the handle is moved The output is configured to provide signals for fault detection circuits and a center tap provides an accurate voltage reference for the lever in its released position or a ze...

Page 5: ...ange 5 k spring return to center 0003 Short lever 25 to 75 Vs output range 5 k spring return to center 0005 Long lever 10 to 90 Vs output range 5 k spring return to center 0006 Long lever 25 to 75 Vs...

Page 6: ...d The degree to which the output is reduced can be chosen from the Code B table in Model code summary on page 5 Position switches Position switches are a standard JS120 feature The normally open switc...

Page 7: ...7 Short lever JS120 is designed to be fitted down into the panel through the panel cutout Panel seal integrity can be achieved by using sealing gasket Mounting screws can be driven to a recommended t...

Page 8: ...Not used D supply ground supply ground C Output voltage Output voltage B supply power supply power A Center tap Not used Marker on underside of mating connector indicates pin G Mating connector detail...

Page 9: ...ut one turn every 10 cm 4 in Use wire harness anchors that will allow wires to float with respect to the machine rather than rigid anchors C Caution Unused pins on mating connectors may cause intermit...

Page 10: ...ary switch Disable all joystick functions that the joystick controls when this switch is released Ensure the control system looks for the appropriate system enable switch input before the joystick is...

Page 11: ...of center 1 tolerance Insulation resistance 50 M at 500 Vdc Load resistance minimum 10 k Load current maximum 2 mA resistive Output voltage curve 90 50 10 Y Y kwa1390403298242 Mechanical characterist...

Page 12: ...o 70 C 13 F to 158 F Storage temperature 40 C to 85 C 40 F to 185 F Environmental sealing above the flange IP 66 above panel IP 40 below panel Technical Information JS120 Single Axis Fingertip Joystic...

Page 13: ...Technical Information JS120 Single Axis Fingertip Joystick Danfoss December 2016 520L0877 BC00000075en US0303 13...

Page 14: ...Technical Information JS120 Single Axis Fingertip Joystick 14 Danfoss December 2016 520L0877 BC00000075en US0303...

Page 15: ...Technical Information JS120 Single Axis Fingertip Joystick Danfoss December 2016 520L0877 BC00000075en US0303 15...

Page 16: ...6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No...

Reviews: