background image

IHMC6-3

Original instructions

.

... 8

GB  

.

... 2

FR 

Summary of Contents for IHMC6-3

Page 1: ...IHMC6 3 Original instructions 8 GB 2 FR ...

Page 2: ...RNING It is important that the IHMC6 3 is not mounted directly to any flammable material i e wood It is recommended that the heatsink be speced off the mounting wall using pillars to aid in heat dissipation General Instructions Read these instructions carefully before installation and use Keep this manual for future reference The product may only be used as set out in the assembly and operating in...

Page 3: ...k up to an additional 2 power units allowing you to control 9 individual 2kW outputs or 8 other power units allowing you to control 9 power units the 3 outputs within each power unit will increase at the same level in this configuration up to 54kW in total 2kW x3 outputs x 9 Power units Note see installation for output options HMI BUTTONS CHANNEL Increment channel selection 1 to 9 CHANNEL Decremen...

Page 4: ...ll pulse Using the HMI push buttons step through the channels and power levels indicated by the UP and DOWN arrows on the fascia Leave all three channels powered up to three different output levels press the ALL ON OFF button once this will turn all three channels off press the button again this will reinstate the outputs to the power levels previously selected Pressing the CH OFF button turns the...

Page 5: ...IHMC6 3 is designed to accept a 230V one phase supply The unit has a 2 stage supply filter to meet EMC legislation and comes in an IP65 rated enclosure complete with glands A 4 core low voltage cable is required to wire the Power unit to the HMI allow it to be mounted neatly away from the main installation The Interface unit is designed to be used with the Remote handset however you can also contr...

Page 6: ...IHMC6 3 12 INSTALLATION CIRCUIT Table A Table B 4 core low voltage cable Neutral 3 phase supply 400V AC 50Hz Earth Load 1 Output Max 2kW Load 2 output Max 2kW Load 3 Output Max 2kW ...

Page 7: ...up 1000 Switch setup 1100 Switch setup 0111 Mapped channels 1 2 3 Mapped channels 4 5 6 Mapped channels all 7 TABLE A TABLE A TABLE B Example 2 Control 1 Control 2 Control 3 Switch setup 1000 Switch setup 0100 Switch setup 0101 Mapped channels 1 2 3 Mapped channels all 4 Mapped channels all 5 TABLE A TABLE B TABLE B Option 2 shows 9 Power units offering 9 channels which can vary from 1 to 10 note ...

Page 8: ...19 04 26 CH Main office Frico AB Tel 46 31 336 86 00 Industrivägen 41 SE 433 61 Sävedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net ...