7
7.4
Commissioning functions
7-713
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
7.4
Commissioning functions
The commissioning functions and support tools help during start–up,
during service, when optimizing the drive, and troubleshooting.
The ”SIMODRIVE 611 universal” control board has the following com-
missioning and help functions:
Function generator (FG)
refer to Chapter 7.4.1
Trace function
(refer to Chapter 7.4.2)
Test sockets (DAU1, DAU2)
refer to Chapter 7.4.3
Measuring function
(refer to Chapter 7.4.4)
!
Caution
Setpoints entered via analog inputs (e.g. via terminals 56.x/14.x and/or
24.x/20.x) or speeds entered via PROFIBUS–DP are added when the
function generator starts.
Note:
The analog inputs can be disabled via P0607 = 0 (for terminal
56.x/14.x) or P0612 = 0 (for terminal 24.x/20.x).
Note
For a ”SIMODRIVE 611 universal” control board, only 1 function
generator or 1 measuring function can be started at the same time,
i.e. either for drive A or B.
The SimoCom U parameterization and start–up tool can, in the online
mode, start the commissioning functions ”function generator” and
”measuring function” with the control authority for PG/PC.
Note
If online operation between SimoCom U and ”SIMODRIVE 611
universal” is interrupted while a start–up function is being executed,
then this start–up function is exited, and an appropriate fault is
displayed on the display unit.
Overview
Start–up
(commissioning)
functions and
”SimoCom U” tool
7 Fault Handling/Diagnostics
01.99