6
6.4
Input/output terminals of the control board
6-502
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-48
Overview of the output signals, continued
Operating
mode
Signal name, description
PROFIBUS bit
pos
n–set
Fct. No.
Status, block selection 1st output/2
0
2nd output/2
1
3rd output/2
2
4th output/2
3
5th output/2
4
6th output/2
5
50
51
52
53
54
55
x
x
x
x
x
x
x
x
x
x
x
x
AktSatz.0
AktSatz.1
AktSatz.2
AktSatz.3
AktSatz.4
AktSatz.5
Ready to be powered–up/not ready to be pow-
ered–up
–
x
x
ZSW1.0
No OFF 2 present/OFF 2 present
–
x
x
ZSW1.4
No OFF 3 present/OFF 3 present
–
x
x
ZSW1.5
Power–on inhibit/no power–on inhibit
–
x
x
ZSW1.6
No following error/following error
58
–
x
ZSW1.8
Spindle position reached (from SW 5.1)
59
x
–
MeldW.15
Control requested/no control possible
–
x
x
ZSW1.9
Comparison value reached/comparison value not
reached
–
x
–
ZSW1.10
Reference position reached/outside reference posi-
tion
60
–
x
ZSW1.10
tion
x
–
Meldw.14
Reference point set/no reference point set
61
–
x
ZSW1.11
Setpoint acknowledge
62
–
x
ZSW1.12
Teach–in executed (from SW 4.1)
64
–
x
PosZsw.15
Drive stationary/drive moving
–
–
x
ZSW1.13
Function generator active (from SW 6.1)
–
x
–
ZSW1.13
First speed setpoint filter inactive
–
x
x
ZSW2.3
Ramp–function gen. inactive
–
x
x
ZSW2.4
Actual motor
1st signal
(from SW 2.4)
2nd signal
–
–
x
x
–
–
ZSW2.9
ZSW2.10
Motor being changed over (from SW 3.3)
–
x
–
ZSW2.11
Slave sign–of–life (from SW 3.1)
–
x
x
ZSW2.12
ZSW2.13
ZSW2.14
ZSW2.15
Suppress fault 608 active (from SW 3.1)
–
x
x
ZSW2.8
Traverse to fixed end stop active (from SW 3.3)
66
–
x
PosZsw.14
External block change (from SW 7.1)
67
–
x
AktSatz.14
6 Description of the Functions
01.99
! 611ue diff !