A
A.1
Parameter list
A-803
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1023
IM diagnostics
Min
Standard
Max
Unit
Data type
Effective
–
–
–
Hex
Unsigned16
RO
Bit 0
Light source failed
Bit 1
Signal amplitude too low
Bit 2
Code connection erroneous
Bit 3
Overvoltage
Bit 4
Undervoltage
Bit 5
Overcurrent
Bit 6
Battery must be changed
Bit 7
Control check error
Bit 8
EnDat encoder cannot be used
Bit 9
CD track for ERN1387 encoder erroneous or
EQN encoder connected, or
incorrectly parameterized (not on EQN, P1027.3)
Bit 10 Protocol cannot be exited
Bit 11 No encoder connected, or
incorrect encoder cable
Bit 12 TIMEOUT for measured value read
Bit 13 CRC error or parity error
Bit 15 Defective measuring encoder
Note:
IM ––> Indirect measuring system (motor encoder)
Bit 7 and 13 = 1 ––> Incremental and absolute track do not match
ERN: incremental encoder system
EQN: absolute encoder system
1024
IM grid spacing (SLM)
Min
Standard
Max
Unit
Data type
Effective
0
20000
8388607
nm
Unsigned32
PO
(SLM)
Note:
IM ––> Indirect measuring system (motor encoder)
1025
IM serial number, low part (SRM SLM)
Min
Standard
Max
Unit
Data type
Effective
0
0
FFFF
Hex
Unsigned16
PO
(SRM SLM)
Note:
IM ––> Indirect measuring system (motor encoder)
1026
IM serial number, high part (SRM SLM)
Min
Standard
Max
Unit
Data type
Effective
0
0
FFFF
Hex
Unsigned16
PO
(SRM SLM)
Note:
IM ––> Indirect measuring system (motor encoder)
A Lists
01.99
! 611ue diff !