7
7.3
List of faults and warnings
7-653
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
177
Start-up passive referencing P179 not possible
Cause
The start-up help for passive referencing determines the reference
point offset in P0162 in the slave drive. The following prerequisites
must be available:
– (permanent) position coupling exists to the master drive
– Master drive must be precisely at its reference point
– Slave drive has passed the zero mark.
Remedy
– Establish a coupling at the slave drive: PosStw.4 or input terminal
function 72/73
– Reference the master drive: STW1.11 or input terminal function 65 at
the master drive
– ”Wiring” check: The requirement for passive referencing must be
transferred from the master to the slave drive:
Masterdrive: Output via ZSW1.15, QZsw.1 or output terminal function 69
Slave drive: read-in via STW1.15, QStw.1 or input terminal function 69
Acknowledgement RESET FAULT MEMORY
Stop response
STOP II
180
Teach-in without reference point
Cause
Teach-in only possible for a referenced axis.
Remedy
Request reference axis and teach in
Acknowledgement RESET FAULT MEMORY
Stop response
STOP IV
181
Teach-in block invalid
Cause
The specified teach-in block is invalid.
Remedy
Specify the valid and existing traversing block.
Acknowledgement RESET FAULT MEMORY
Stop response
STOP IV
182
Teach-in standard block invalid
Cause
The specified teach-in standard block is invalid.
Remedy
Specify the valid and existing traversing block.
Acknowledgement RESET FAULT MEMORY
Stop response
STOP IV
183
Teach-in block not found
Cause
The specified teach-in block is not found.
Remedy
Select the valid and existing traversing block.
Activate ”Automatically search for block numer” function.
Acknowledgement RESET FAULT MEMORY
Stop response
STOP IV
7 Fault Handling/Diagnostics
01.99
04.05