background image

          GAUGEMASTER 

®

 

 

 

MODEL ‘COMBI’ SINGLE TRACK CONTROLLER 

 

FOR INDOORS USE ONLY

 

 
The controller and power supply should be regularly examined for potential hazards such as damage to the casing, cable or plug, 
connectors etc. In the event of any damage to either of the units, they should not be used until the damage has been repaired. The 
units are sealed and having no repairable components should not be opened. A repair service, for the controller only is available at 
the address shown below. 
 

WALL MOUNTED TRANSFORMER WM1:

  Input:   220 – 240V AC at 50Hz BS1363 flat pin moulded plug. 

Output:  18V AC @ 1.1Amps @ 25 deg C via 2.1 x 10 mm power socket and cable. 
The secondary winding is fitted with a Positive Temperature Coefficient (PTC) Thermistor which will prevent thermal damage 
should an over load condition occur. In this event the unit must be disconnected from the mains supply. Having established and 
rectified the reason for the over load reconnect the Wall Mounted Transformer WM1 to the mains supply. 
The primary winding is fitted with a once only thermal fuse. In the unlikely event this should operate then the unit is defunct and 
a replacement should be sourced. The unit is a single wound transformer and should not be used to power more than one 
controller.  

CAUTION: It is very important that the outputs of two or more control units are not connected 
together 
in parallel.  i.e. outputs linked. If done, there is a risk of electric shock from a plug not inserted into a 
socket.  

 

COMBI CONTROLLER: 

Some self adhesive pads are supplied for fixing your Model COMBI to your baseboard if desired. 

Connect the terminals marked "Track" to the section or track you wish to operate. Plug the output lead of the Wall Mounted 
Transformer WM1 into the socket on your COMBI and then plug the Wall Mounted Transformer WM1 into a 220/240V ac 
supply. Operate the output control knob and observe the track supply indicator LED that should vary in brightness with the output 
voltage. Turn the output control knob to off and locate a suitable locomotive onto your track. Slowly apply power using the 
output control knob. Reverse the DC output connections if the locomotive travels in the wrong direction.  The unit is suitable for 
Cab Control and Common Return wiring providing individual power supplies are used for each controller. Please ensure 
tracks/sections are correctly isolated from each other. The outputs of two or more control circuits must not be connected in such a 
way that a short circuit occurs, i.e. through switches or points, etc. A thermal response cutout device protects all outputs. 

Connected power supplies such as Gaugemaster WM1, T1 or M1 should only be connected via the designated input power 
socket and under no circumstances should an external supply be connected into the 16/18V AC Accessories terminals. 
Connection of the COMBI controller to a power supply other than Gaugemaster models WM1, T1 or M1 will invalidate 
your warranty. 

 

ACCESSORIES: 

The “16/18v AC Accessories" terminals are for use with point motors and other electrical accessories, but are 

not suitable for Common Return wiring with the DC output. When used for point motors it is advisable to use a Capacitor 
Discharge Unit (CDU) to ensure successful operation.  
 

OPERATION: 

The output on your GAUGEMASTER controller is fitted with an LED that is extinguished at zero output. 

Dependent upon the control level selected the brightness of the LED will change. Should the LED extinguish or remain 
extinguished irrespective of the control knob position then a fault condition has occurred and the unit has ‘tripped’. Should an 
overload condition be detected output will be greatly reduced and in most cases no output will be apparent. To reset the unit, 
having first investigated and rectified the reason for the overload, turn the control knob to and zero and set the direction switch to 
its central ‘OFF’ position. Wait approximately 2 minutes before using the equipment as normal. Please note that whilst a tripped 
condition exists it may be possible to measure a small no load voltage at the output. This is normal. 
This unit is suitable for use with all types of motors, including Portescap, and High Frequency Track Maintainers. 
 

COMBI OUTPUTS:

             0-12V DC controlled (nominal), up to 1amp @ 25 deg. C and 18V  AC  (nominal),  50Hz,  up  to  1amp 

@ 25 deg. C 
NB. Maximum total rated output - 1amp @ 25 deg. C 

 

GUARANTEE:

 

We undertake to replace, free of charge, any parts found defective within the lifetime of the unit, providing the 

item has not been tampered with and parts are still available for such a repair. The guarantee on the Wall Mounted Transformer 
WM1 is limited to replacement of units found to be defective by manufacture. This guarantee covers only the supply of 
replacement parts, labour cost for fitting of same and the cost of returning the unit to the customer or retailer. This Guarantee does 
not affect your Statutory Rights. We reserve the right to vary design or specification without notice. 
 

                                                                CONSTRUCTED TO EN60 742/ EN61558-1                                         

 

 

Gaugemaster Controls Ltd, Gaugemaster House, Ford Road, Arundel, West Sussex  BN18 OBN   

Tel. No:  01903 884321  Fax. No:  01903 884377  Email: [email protected]   Web: 

www.gaugemaster.com 

All manuals and user guides at all-guides.com

Reviews: