Overview

RTS-2HS Model

The Temperature Sensor (RTS) uses wireless
technology to communicate accurate room
temperature from 0°C to 40°C (32°F to 104°F)
and relative humidity from 20% to 92%. The
sensor provides current and on-change values
for target controllers to manage the
environment of a space.

The RTS is available in two radio frequencies,
902 MHz and 868 MHz. The core model
(RTS-1T) monitors temperature. Additional
models are available that also monitor relative
humidity (RTS-1H), provide a temperature set
point (RTS-1TS), and include all RTS features
including fan speed control and an occupancy
signal (RTS-2HS).

The RTS is solar powered and can store energy
to maintain operation during periods of low
light—up to 200 hours in darkness. A CR2032
battery can be used for running tests or backup power assistance, if
required. Color LEDs are visible through the solar panel to indicate the
sensor's operation.

The RTS is well suited for occupancy-based hospitality applications that
require control to power a room or setback temperature control devices.

This document covers installation and tests that apply to all RTS models.
The product package includes the sensor and installation guide.

Summary of Contents for RTS

Page 1: ...nvironment of a space The RTS is available in two radio frequencies 902 MHz and 868 MHz The core model RTS 1T monitors temperature Additional models are available that also monitor relative humidity R...

Page 2: ...xtures in the space may disrupt wireless transmissions Install the sensor within range of linked receivers or controllers 24 m 80 ft Consider adding a repeater to extend reception range Before linking...

Page 3: ...double sided tape or Velcro not provided Over a standard Class 2 low voltage electrical box Keyholes in the back plate mate with standard screw patterns 1 Insert a flatblade screwdriver into the slot...

Page 4: ...ounterclockwise to lower and clockwise to increase The receiving control equipment interprets the set point value to an offset range For no offset point the arrow on the dial straight up Fan Speed Con...

Page 5: ...ransmission 4 Deactivate Link mode on the controller before attempting to link to any other controllers Battery Power A battery is not required for normal operation if the sensor receives adequate nat...

Page 6: ...LED 2 Press and hold the Test button again until the green LED stops blinking The green LED then repeats a number of blinks according to the detected light level The sensor reevaluates the light level...

Page 7: ...Any modifications or changes to this product not expressly approved by Electronic Theatre Controls Inc could void the user s authority to operate the product Operation of this equipment in a resident...

Page 8: ...Echoflex Installation Guide Temperature Sensor Temperature Sensor Page 8 of 8 Echoflex...

Reviews: