background image

B614

Summary of Contents for B614

Page 1: ...B614...

Page 2: ...Alle vermelde namen en merken zijn eigendom van de respectievelijke fabrikanten Deklantenmogenkopie nmakendieenkelvooreigengebruikbestemdzijn Dez handleiding werd in 2018 gepubliceerd Copyright FAAC...

Page 3: ...heessentialrequirementsoftheMachineryDirective2006 42 EC includingallapplicableamendments thathavebeenappliedand fulfilled are as follows 1 1 2 1 1 3 1 1 5 1 2 1 1 2 3 1 2 5 1 2 6 1 3 1 1 3 2 1 3 4 1...

Page 4: ...22 Round beam 24 5 5 Fitting the spring 26 Turnbuckle 26 Single spring 27 Double spring 27 5 6 Accessories on the beam 28 5 7 Balancing the beam 28 5 8 Limit switch adjustment 29 5 9 Earthing the doo...

Page 5: ...61 Deleting radio controls from memory 46 9 4 BUS 2easy devices 47 Connection 47 BUS 2easy photocells 47 Control devices 47 BUS 2easy device registration 48 9 5 Round beam light kit 49 9 6 Integrated...

Page 6: ...s for the installation maintenance technician technical personnel Risks for the user of the automation system Risks to product integrity damage In Europe the automation of a barrier falls under the Ma...

Page 7: ...G Riskofimpact crushing or shearing due to moving parts RISKOFOBJECTSFALLINGFROMABOVE Riskofimpact due to objects falling RISK OF TRIPPING Risk of tripping due to raised sections above 5 mm RISKS FROM...

Page 8: ...onto the market as partly completed machinery therefore it cannot be com missioned until the machine in which it will be incor porated has been identified and declared to conform to the Machinery Dir...

Page 9: ...ty footwear 20 kg is the MAX weight one person can lift Kg ____ Weight of package PALLETISED SUPPLY RISKS PERSONAL PROTECTIVE EQUIPMENT SINGLE PACKAGE RISKS PERSONAL PROTECTIVE EQUIPMENT Use a forklif...

Page 10: ...of the packaging materials The packaging materials plastic polystyrene etc must not be left within reach of children as they are potential sources of danger When you have finished with them dispose o...

Page 11: ...vely vehicle access control must be fitted with suitable visible signs prohibiting foot traffic A separate route for foot traffic outside therangeofthebeammustbeprovidedandproperly indicated Iffoottra...

Page 12: ...o corrosive chemicals or atmospheric agents Do not expose the barrier to direct jets of water of any type and size Do not expose the barrier to aggressive chemical or environmental agents Thebarrierma...

Page 13: ...f an obstacle during closure cau ses the manoeuvre to be reversed the recognition of an obstacle during opening causes the beam to stop Adjustable end of stroke The barrier is fitted with an adjustabl...

Page 14: ...305 mm FAAC beam Beam length Rectangular beam 1 35 4 85 m max Round beam 1 40 5 20 m max 6 Technical data 3 7 MANUAL OPERATION Performing the release manoeuvre when there is no electrical power Perfor...

Page 15: ...ard equipment on the barrier body 4 1 Bearing trunk 2 Drive shaft 3 Beam release device triangular key 4 Top cover 5 Door with lock 6 E614 control board 7 E614 control board cover 8 Balancer upper spr...

Page 16: ...gular or round beam the reflecting paper for round beam are supplied separately 3 Fixing pocket for the installed beam rectangular or round 4 Single or double balancing spring 3 10 OPTIONAL ACCESSORIE...

Page 17: ...nloops refertothespecific instructions Presence of a safety area between the wall or other fixed element and the end of the beam to protect against the risk of persons becoming trapped crushed Presenc...

Page 18: ...e plans to ensure that there are no other electrical cables in proximity to the planned digging drilling locations to prevent the risk of electrocution Check that there are no pipes in the vicinity as...

Page 19: ...E SYSTEM The example is purely an illustration and is only one of the possible applications of the B614 Example system Minimum wire cross section 1 Barrier B614 2 Mains power supply 3G 1 5 sq mm 3 Cir...

Page 20: ...ectronic parts and the moving mechanical pars Never install the beam before fixing the barrier body and checking it Untiltheinstallationiscomplete neverleavethebar rier unguarded with the beam fitted...

Page 21: ...d dimensions on the basis of the characteristics of the ground and place of installation Perform structural calculations where necessary 1 Make the hole in the ground Fill it with concrete allowing th...

Page 22: ...t the plinth s concrete has solidified In this phase the barrier must be locked Nevermanagethebarrierbyholdingtheboardholder 1 10 Removethe4nutswithwashersfromthe plate 2 11 Placethebarrierbodyonthefo...

Page 23: ...of cable are necessary 1 13 Arrange the cables inside the barrier Fix the cables with the cable ties provided 1 2 and 3 2 14 Remove bolt with washer 1 Open cable tie 2 Bring the cables to the board 3...

Page 24: ...o turn the balancer in the closed beam position This phase requires the release of the barrier Keep away from the moving elements inside the box To move the balancer turn the drive shaft making use if...

Page 25: ...esting it at the end 6 Line up the two holes underneath slide the lower edging temporarily to uncover the holes 7 Fixthebeamwithscrews2 interposingthewashers reposition the lower edging 8 19 Insertcov...

Page 26: ...m L LThe spacer 5 must not be used and must be elimi nated 3 22 Removing guide 1 and replacing it 4 Insert the adaptor 2 horizontally 5 Fix in position with screw 3 interposing washers 4 and 5 Usethet...

Page 27: ...nal instructions ENGLISH 9 24 Insert cover 1 and fix it with the screws 2 10 25 Applythereflectivepapers1onbothsides of the beam 11 Insertcover2attheendofbeamandfixwithscrews3 Leave the beam supported...

Page 28: ...ng to the balancer and the base indicated The accessories on the beam must be considered when choosing the balancing spring single or dou ble Following the addition or elimination of the accessories a...

Page 29: ...nsion Keep away from the spring coils 4 Restore the automatic operation DOUBLE SPRING 1 Lengthentheturnbucklebymanuallyunscrewing it to facilitate the operation 2 Lower bracket 29 Connect the plate 1...

Page 30: ...cessories to the beam 5 7 BALANCING THE BEAM RISKS PERSONAL PROTECTIVE EQUIPMENT This phase requires the release of the barrier Performing the release manoeuvre when there is no electrical power Keep...

Page 31: ...his phase requires the release of the barrier Performing the release manoeuvre when there is no electrical power Keep away from the moving elements inside the box and from the coil spires Do not leave...

Page 32: ...nd nut on the base and on the door Respect the insertion order indicated in the figure 5 10 CLOSING THE DOOR The door must be closed before any manoeuvres are performed even manually Handle the door c...

Page 33: ...ith the cover inclined insert markers 1 in slots 2 on the box rod side then lower it on the opposite side 2 Close with the key turn in an anticlockwise direction 3 Check the closure of the cover try t...

Page 34: ...erating temperature 20 C to 55 C 20 C to 55 C COMPONENTS See figure 35 BOARD J1 Mains power supply terminal board J3 BUS 2easy terminal board J6 Accessory input terminal board J7 Connector for XF radi...

Page 35: ...UT 3 OUT 2 OUT 1 24V LAMP MOT MOT PE N L N L 6 A M 24 V 15 W max RADIO 1 RADIO 2 ERROR ALARM F XF 433 868 AC MAIN MOT ENC TRAFFIC LAMP LIGHT BEAM COM BLR BLG F3 J8 J1 J23 J11 J18 J21 J6 J10 J3 J13 F J...

Page 36: ...other pulse giver that commands the closure of the barrier by closing a contact 3 STOP Configured as STOP default NC contact connect a button or other pulse giver that commands the stopping of the ba...

Page 37: ...e necessary 37 Connectthemagneticcoildetectorstotermi nal boards J10 LOOP 1 or J13 LOOP 2 LOOP 1 Opening coil NO contact connect a detector that commands the opening of the barrier when a contact is c...

Page 38: ...mation system to operate BEAM LIGHTS See 9 5 and 9 6 for the connection INTEGRATED FLASHING LIGHT 40 See 9 6 for the connection XBAT 24 BATTERY 41 See 9 2 for the connection XF RADIO MODULE 41 See 9 3...

Page 39: ...properly set the parameter cF dependent on the beam length 6 RegistertheBUS2easydevices iftheyareinstalled see 9 4 7 Check the barrier s direction of travel see 11 2 8 Perform the set up see 7 3 9 If...

Page 40: ...4m 03 beam from 4m to 5m 03 dF DEFAULT Displayed if the board is configured with the factory settings default Y indicates that all set values correspond to the defaults no indicates that one or more s...

Page 41: ...nimum power 50 maximum power 50 SP STOP INPUT CONFIGURATION It defines the function of the STOP input 00 STOP Stop 02 FSW CL Closure photoelectric cell 00 t OPERATINGTIME time out Set a higher value t...

Page 42: ...sonwithbarrierclosed offwithbarrier in pause mode open flashing during the move ment 02 lights off with barrier in pause mode open flashing in all other states 01 AS MAINTENANCEREQUEST CYCLECOUNTER li...

Page 43: ...ion of the photocells during the pause mode reloads the pause time OPEN during the opening locks OPEN during opening causes it to open again L LThe CLOSE command always commands the closure b SEMI AUT...

Page 44: ...approaching the automation system until the end of the procedure L LThe SET UP MUST be performed with the mains power switched on with the automation system functioning auto matically with the STOP EM...

Page 45: ...over see the relative section 2 4 3 Apply the notice supplied warning against the risk of cutting crushing or the loss of fingersorahandbetweenthebeamandthebody of the barrier The indication of the RI...

Page 46: ...ind If it is raining an adequate shelter for the barrier must be madeuntilthemechanicalandelectronicinstallation is complete Nevermanagethebarrierbyholdingtheboardholder 9 1 24V FLASHING LIGHT The fla...

Page 47: ...n succession to complete the memorisation process If the procedure was carried out correctly the B614 will open the beam if permitted by the operating mode that has been set SLH SLH LR MEMORISING OTHE...

Page 48: ...OPEN program ming or CLOSEprogramming Afterpressing thebuttonforabout5seconds thecorresponding radioLED DL4orDL5 willstarttoflashtoindicate that the radio code learning phase has started 3 Release the...

Page 49: ...2easy photocells 11 Orienting the photocells 1 0 0 0 CL FSW 1 0 0 1 1 0 1 0 1 0 1 1 1 1 0 0 1 1 1 0 1 1 1 1 OPEN Assignanaddresstoeachpairofphotocellsbysetting thefourDIPswitches DS1 onthetransmittera...

Page 50: ...s been replaced Following any changes addition replacement or removal to the BUS 2easy devices ON 1 2 3 4 5 1 command DIP switch 5 0 OFF ON 1 2 3 4 5 2commands DIPswitch5 1 ON Registration procedure 1...

Page 51: ...Connect the flashing light to terminal J21 4 Set the operating mode oS in Advanced pro gramming 5 Close the upper cover 6 Check that the device is working properly 9 7 BEAM JOINT KIT Follow the assem...

Page 52: ...d is in good condition You should install a beeper or similar to indicate the beam is closing Apply the reflector on the stem L LOn the rectangular beam it is not possible to install the foot when the...

Page 53: ...ernal loops must be connected to the Master barrier Each barrier must be programmed on the basis of the length and configuration of the beam The functio ning logic must only be programmed on the Maste...

Page 54: ...ogramming and set cF depending on the beam configuration and length Ct SL for configuring the board as Slave 3 Check the status of the LEDs on the board LED DL7 Red Master Slave synchronisation absent...

Page 55: ...shows 2 Keep the button pressed The display shows oP and the barrier opens The flashing point betweenthetwolettersindicatesthattheencoder is operating correctly 3 Keep the button pressed The display...

Page 56: ...installer machine manufacturer is re sponsible for drawing up the maintenance plan for the automation supplementing this list or modifying the maintenance intervals according to the machine characteri...

Page 57: ...Fork Check that they are intact and correctly fastened 6 Checkthepresenceandintegrityofallthesignsandmarkings necessary 6 Jointed beam Check that they are intact and correctly fastened 6 Check the in...

Page 58: ...G THE GEARMOTOR 1 Perform the release manoeuvre 2 Lift the beam completely vertically 3 Restore the automatic operation 4 Lengthentheturnbucklebymanuallyunscrewing it to facilitate the operation 5 Unh...

Page 59: ...sa invert the phases in the motor connec tion and perform a SET UP The barrier makes very slow movements check the force set check the balancing of the beam check the parameter cF has been set in acco...

Page 60: ...h are purely indicative and in no way exhaustive help the installer draft the user instructions The installer must provide the owner operator of the automation with the EC Declaration the system Logbo...

Page 61: ...y for the entire stroke Do not let the beam travel freely Do not leave the barrier unblocked after carrying out the manual movement restore automatic operation RELEASE PROCEDURE 1 53 Open the lock cov...

Page 62: ...60 53 60x60x60h 52 52 53 53 20 20 20 20 POS 1 5 10 POS 1 5 10 POS 2 5 10 POS 2 5 10 POS 5 4 10 POS 5 4 10 POS 5 4 10 POS 4 5 10 POS 4 5 10 POS 3 5 10 POS 3 5 10 Translation of the original instruction...

Page 63: ...max 4 81 m beam and lights 1 B 2 B 3 A 4 A 5 A 3 A 4 A beam length min 1 65 m max 2 19 m min 2 20 m max 2 69 m min 2 70 m max 3 09 m min 3 10 m max 3 49 m min 3 50 m max 3 80 m min 3 81 m max 4 30 m...

Page 64: ...2 94 m min 2 95 m max 3 39 m min 3 40 m max 3 75 m min 3 76 m max 4 40 m min 4 41 m max 4 90 m beam and foot 1 B 2 B 3 A 4 A 5 A 3 A 4 A beam length min 1 40 m max 1 89 m min 1 90m max 2 39 m min 2 40...

Page 65: ......

Page 66: ......

Page 67: ......

Page 68: ...FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 09 57 820 www faac it www faacgroup com B614 63 732998 Rev A...

Reviews: