B614 40
732998 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
Advanced function
Default
P1
OUT OUTPUT 1 POLARITY
Y
NC output
no
NO output
If output
o1
=
01
(Fail-safe) configure
P1
=
no
.
no
o2
see
o1
P2
see
P1
o3
see
o1
P3
see
P1
o4
see
o1
P4
see
P1
to
OUT OUTPUT 1 TIMING
(only displayed if one of the outputs is configu-
red as courtesy light)
This defines the timing of the output from 1 to 59
minutes in 1 minute steps.
02
bF
BATTERY OPERATION
01
continues to function until completely dead
02
the barrier opens when the mains power is
interrupted
03
the barrier closes when the mains power is
interrupted
01
oS
INTEGRATED flashing light OPERATING MODE
01
light column (steady green with barrier in
pause mode/open, red flashing during movement,
red steady with barrier closed)
02
flashing light (flashing red during move-
ment, off in all other states)
01
bL
BEAM LIGHT OPERATIONAL MODE
01
lights on with barrier closed, off with barrier
in pause mode/open, flashing during the move-
ment
02
lights off with barrier in pause mode/open,
flashing in all other states
01
AS
MAINTENANCE REQUEST - CYCLE COUNTER (linked
to the next two functions)
This can be useful to set scheduled maintenance
interventions.
Y
Active
no
Excluded
no
nc
CYCLE PROGRAMMING IN THOUSANDS
This makes it possible to set a countdown of the
plant operating cycles from 0 to 99 (thousands of
cycles). The function can be used, in combination
with
nC
, to verify the use of the system and for
the “Request for assistance”
00
…
99
(thousands of cycles)
00
Advanced function
Default
nC
CYCLE PROGRAMMING IN HUNDREDS OF THOU-
SANDS
This makes it possible to set a countdown of the
plant operating cycles from 0 to 99 (hundreds of
thousands of cycles). The value displayed is updated
a the cycles progress, integrating with the
nc
value.
(1
nC
decease corresponds to 99
nc
decreases).
The function can be used in combination with
nc
, to verify plant use and for the "Request for
Assistance".
00
St
AUTOMATION SYSTEM STATUS:
See
St
in the Basic programming
Y