Page 1: ...MAKING MODERN LIVING POSSIBLE Service Manual Steering Unit EH Electro Proportional Hydraulic Valve In line Version powersolutions danfoss com...

Page 2: ...Revisions Date Changed Rev Mar 2014 Converted to Danfoss layout DITA CMS BA Sep 2010 New back cover AB Jun 2010 First edition AA Service Manual EH Electro Proportional Hydraulic Valve In line Version...

Page 3: ...5 Tools Tools 6 Dismantling Dismantling the EH valve 7 Preassembly Inspection cleaning and replacement 13 Cleaning 13 Inspection and replacement 13 Lubrication 13 Reassembly Reassembly of the EH valv...

Page 4: ...lve housing 1 1 Main spool 2 1 PVE 3 1 Plug 4 1 50 5 Filter 5 2 O ring 6 3 O ring 7 1 O ring 8 1 Spring 9 1 PR cone 10 1 PR spool 11 1 Plug 12 1 15 2 Pilot cone and spring 13 1 Adjusting screw 14 1 Pr...

Page 5: ...sing 1 1 Main spool 2 1 PVE 3 1 Plug 4 1 50 5 Filter 5 1 O ring 6 3 O ring 7 1 O ring 8 1 Spring 9 1 PR cone 10 1 PR spool 11 1 Plug 12 1 Pilot cone and spring 13 1 Adjusting screw 14 1 Protection plu...

Page 6: ...2 5 mm 4 mm 5 mm Calibration Torque wrench Small screw driver Magnetized tool O ring pick or similar 3 mm threaded screw Bench vise Tools are not available from Danfoss Service Manual EH Electro Prop...

Page 7: ...ner Carefully pries lose the o ring seals 6 7 and 8 and Screen Mesh Filter 5 from PVE Fasten housing in a vice and remove the spool retainer plug 4 using a 27 mm spanner or socket wrench Service Manua...

Page 8: ...er plug 16 using a 5 mm Allan key This only applies to units with PVFC spool Insert a 3 mm threaded screw into the end of the PVFC spool 18 and use to remove the spool from the housing Service Manual...

Page 9: ...ith a 5 mm Allan key Remove the Pressure Reducing spool 11 from the cavity Remove the Pressure Reducing poppet 10 with a magnetized tool Service Manual EH Electro Proportional Hydraulic Valve In line...

Page 10: ...lot Relief Valve plastic protection cover 15 with a small screw driver or O ring pick Then remove the Pilot Pressure relief valve adjusting screw 14 with a 5 mm Allan key Service Manual EH Electro Pro...

Page 11: ...en installed This only applies to units with dynamic orifice i e units without PVFC spools Pries out the screen mesh filter 20 with a small pick or small screw driver This only applies to units with d...

Page 12: ...fice plug 21 with a 2 5 mm Allan key This only applies to units with dynamic orifice i e units without PVFC spools Service Manual EH Electro Proportional Hydraulic Valve In line Version Dismantling 12...

Page 13: ...and replacement Check all parts carefully and make any replacements as necessary All O rings and screen filters must be replaced Lubrication Before assembly lubricate all parts with hydraulic oil Serv...

Page 14: ...iner hexagonal plug 16 into the housing with a 5 mm Allan key and tighten Remember to lubricate the O ring with light weight grease Make sure that the main directional spool 2 is lubricated with a thi...

Page 15: ...to lubricate the O ring with a small amount of grease Insert PV poppet spring unit 13 into the housing Then screw in PV pressure adjustment setting screw 14 with 5 mm hexagon socket spanner Make sure...

Page 16: ...PV adjustment screw 14 is set to the required pressure on a test bench Insert the Pressure reducing spring 9 into the housing Then the PV poppet 10 must be inserted into the spring stem end first Serv...

Page 17: ...icate the spool first with a thin film of oil Screw in RP retaining plug 12 with 5 mm Allan key Make sure O ring is lubricated If your EH valve has a dynamic orifice function then screw the plug 18 in...

Page 18: ...ng with 4 mm Allan key Carefully place the screen mesh filter 5 dome first into the PVE housing followed by the O rings 6 7 and 8 Remember to use a light grade grease to keep the O rings in place Serv...

Page 19: ...Mount the PVE 3 to EH housing with the four cap screws 17 and tighten with 5 mm Allan key Service Manual EH Electro Proportional Hydraulic Valve In line Version Reassembly L1026660 Rev BA Mar 2014 19...