Remove Pilot Relief Valve poppet/spring unit (13).
(Use O-ring pick or similar).
Screw out the Dynamic Orifice sealing plug (16)
with a 5 mm Allan key if it has been installed.
This only applies to units with dynamic orifice (i.e. units
without PVFC spools).
Pries out the “screen mesh” filter (20) with a small
pick or small screw driver.
This only applies to units with dynamic orifice (i.e. units
without PVFC spools).
Service Manual
EH Electro Proportional Hydraulic Valve In-line Version
Dismantling
L1026660 • Rev BA • Mar 2014
11