Maintenance-Object Repair Procedures
555-233-143
8-256
Issue 1 May 2002
f. Error Type 1793: Layer 2 Query test for the primary signaling channel
failed.
■
Excessive AAL – The AAL layer is experiencing an excessive
number of errors in trying to reconstruct Service Data Unit (SDUs).
Possible causes:
— Problem with the ATM switch
— Noisy communication paths on opposite side of ATM switch
— Unhealthy sending node
— Congestion at the ATM switch
g. Error Type 2305: The Remote Layer 3 Query test (#637) failed. A specific
message was sent to the far-end switch, and it did not respond within the
allotted time.
1. Investigate elements of the ATM D channel(s) (ATM-DCH) for both
this switch and the far-end switch.
If Test #637 fails twice in a row, the B channels are alarmed and made
unavailable for outgoing calls (although incoming calls are still accepted).
When Test #637 succeeds and the far-end switch starts responding
properly, the ATM trunk (B channels) are placed back into normal operation
and their alarms retired.
h. Error Type 3585: A SERV or SERV ACK ISDN D-channel message has
been received by a non-US-type interface (country option other than
1
on
the DS1 administration form). However, these messages are used only for
duplex NFAS signaling, which is supported by country protocol 1.
Thus, there may be a mismatch in administration between the local and
far-end switches.
1. Consult with the customer’s network provider to determine whether
the D channel is set up correctly on the far-end switch.
i. Error Type 3840-3928: These error types are used to report certain error
messages received by the ATM-SGRP Signaling Group for one of its
associated B channels. The Aux Data field is the port number of the
B channel from which the message was received.
The error code generated equals 3840+x, where x is a Cause Value
defined by the ISDN PRI Specification. Note that there is no Test to Clear
Value for these error types; selected ISDN cause values are placed in the
log when they are received, but no direct action or alarming is performed
solely in response to receiving them. They provide added data that may
prove useful when tracking down obscure networking and routing
problems.
provides more information about
this range of Error Codes:
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...