Maintenance-Object Repair Procedures
555-233-143
8-338
Issue 1 May 2002
NPE Crosstalk Test (#617)
This test is destructive.
One or more NPEs reside on each circuit pack with a TDM-bus interface. The
NPE controls port connectivity and gain, and provides conferencing functions on a
per-port basis. The NPE Crosstalk test verifies that this port’s NPE channel talks
on the selected time slot and never crosses over to time slots reserved for other
connections. If the NPE is not working correctly, one-way and noisy connections
may be observed. This test is part of a port’s long test sequence and executes in
approximately 20 to 30 seconds. Crosstalk testing is performed on both
B channels (B1 and B2) associated with a BRI port. If this test fails on either
channel, any endpoint connected to the port is taken out-of-service.
This test is not executed for ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT
because the B channels associated with the port are not used by ASAI or Avaya
adjuncts.
Table 8-143.
Test #617 NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port PCSSpp command to determine the station
extension or trunk group/member number of the port. Use the status
bri-port PCSSpp command to determine the service state of the port. If
the service state indicates that the port is active, then the port is
unavailable for certain tests. (Refer to the “Status Commands” section in
Chapter 7, ‘‘Maintenance Commands’’
, for a full description of every
possible state.) Wait until the port is idle before retesting.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
3. If the test continues to abort, escalate the problem.
1004
ABORT
The port has been seized by a user for a valid call.
1. Use the status station command for the station associated with this port
and determine when the port is available for testing.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort and the port is idle, escalate the problem.
1005
ABORT
This test is not valid for this type of translation. Ports administered as “ASAI” or
“ADJK” cannot run this test, because the B channels associated with the port
are not used by ASAI or Avaya Adjunct Links. This is a normal condition.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...