EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-801
555-233-143
1139
ABORT
The packet bus in the PN where this EI board resides has a major alarm
against it. This test needs to use the alarmed PN’s packet bus.
1. Enter display alarms and display errors and resolve any PKT-BUS
alarms.
2. Retry the command.
1141
ABORT
The Packet Interface circuit pack is out of service.
1. See
‘‘PKT-INT (Packet Interface)’’
1144
ABORT
The PN’s packet bus has a major alarm against it. This test needs to use the
alarmed PN’s packet bus.
1. Enter display alarms and display errors and resolve any PKT-BUS
alarms.
2. Retry the command.
1394
ABORT
The EI board is out of service and the test cannot be run. This condition is due
to a change in the EI board’s ability to communicate with the EI or SNI circuit
pack on the other end of the fiber.
1. Run Test #237 and check the Error Log for EXP-INTF Error Type 1281. If
Error Type 1281 is present or if Test #237 fails, see repair procedures for
Test #237, in
1395
ABORT
This test cannot be run on an EI circuit pack if it is part of the B-side PNC and
duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, enable PNC with the change
system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the set
PNC lock command.
3. Repeat this test.
1407
ABORT
This test cannot be run on an EI board that is on the active PNC because it
cannot be busied out. This error code indicates that PNC duplication is
enabled.
1. Attempt to perform a PNC interchange via the reset pnc interchange
command.
2. If the PNC interchange is successful, busyout the original EI circuit pack
via the busyout board UUCSS (address of the original EI board).
3. Retry the command.
2000
ABORT
Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
Table 8-307.
Test #242 Expansion Interface Lightwave Transceiver Looparound
—
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...