TTR-LEV (TTR Level)
Issue 1 May 2002
8-1699
555-233-143
When a user goes off-hook to place a call, dial tone is returned to the user,
indicating that a tone detector is connected and ready to receive and interpret
tones. The tone detector is in use until the total number of digits needed is
collected or until a time-out occurs. If every tone detector in the system is being
used simultaneously, the next user to go off-hook will not receive dial tone until a
tone detector becomes available. It is therefore necessary to have a sufficient
number of tone detectors in the system to prevent delays in receiving dial tone.
The list measurements tone-receiver command shows the level of tone
detector usage.
In order to prevent dial-tone delays and other shortcomings in system
performance, threshold levels for the 3 types of tone receivers are administered
on the change system-parameters maintenance form. Whenever the number
of tone receivers in service falls below the administered threshold for that type of
tone receiver, an alarm is logged against the TTR Level MO. At this point, the
system is operating properly, but call processing capacity is reduced. Another
alarm is logged if the number falls to zero. At this point, system operation is
severely compromised.
Typical causes of these events are:
1. The threshold for GPTD-PTs or DTMR-PTs is administered incorrectly on
the maintenance-related system parameters form.
2. Too many GPTD-PTs, DTMR-PTs, or CLSFY-PTs have been taken out of
service, possibly by maintenance software or a demand busyout.
3. A tone detector circuit pack has been removed or suffered a fatal failure,
resulting in the loss of all its ports.
4. The system has an insufficient number of TN748/TN744/TN420 circuit
packs.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...