PKT-INT (Packet Interface)
Issue 1 May 2002
8-1263
555-233-143
Running this test on the active IPSI circuit pack’s Packet Interface circuit reads
and clears the Parity Error counter and FIFO Overflow counter. Those counters
are not used when an IPSI’s Packet Interface circuit is in standby mode.
Running this test on the standby IPSI circuit pack’s Packet Interface circuit, reads
but does not clear a Translation RAM counter. The Translation RAM counter is
not cleared since the number of bad translations RAM locations indicates bad
locations that cannot be used. For an active Packet Interface circuit, information
about the number of bad Translation location is sent to maintenance software as
an in-line error from the circuit pack so it is not necessary to read a counter
location.
Table 8-512.
Test #887 Read and Clear Board Counters
Error
Code
Test
Result
Description / Recommendation
1006,
1137
ABORT
The IPSI circuit pack’s Packet Interface circuit is out of service, so normal
maintenance tests do not run on the circuit pack.
1. Enter the reset packet-interface Uc command to reset the Packet
Interface circuit. For repair procedures, see
,
the Packet Interface Reset test.
1335
ABORT
Internal IPSI error. The test is on standby IPSI’s Packet Interface circuit, so
this test is not allowed to execute.
1. To run this test on the standby Packet Interface circuit, enter set
ipserver-interface Uc to activate it.
2000
ABORT
Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABORT
Internal system error
1. Retry the command.
NO
BOARD
The IPSI circuit pack’s Packet Interface circuit is administered, but is not
detected as being physically present.
1. If the IPSI circuit pack is present, replace it.
2. If not, insert a TN2312AP IPSI circuit pack in the administered slot, and
rerun the test.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...