Alarms, Errors, and Troubleshooting
555-233-143
4-56
Issue 1 May 2002
Figure 4-35.
A500: show switch circuit screen
■
The pp VBRnrt (Variable Bit Rate) virtual circuits between A500 ports A1.1
(PPN) and A1.2 (EPN) are used for signaling between the PPN and each
EPN.
■
These are established once upon initialization under control of S8700
Multi-Connect call processing. They represent the ATM Control Link (ACL)
and Expansion Archangel Link (EAL).
■
VBRnrt virtual circuits are also be used for ISDN channels between S8700
Multi-Connect port networks.
■
Other VBRnrt virtual circuits may exist between A500 ports that are not
associated with S8700 Multi-Connect port networks. A common use of
VBRnrt circuits is multimedia and video-conferencing systems.
CaPro Layer
Are talk paths being established between port networks?
Diagnostics
■
Can you talk both ways on a set on one port network dialed from another
port network, and vice versa?
1. Enter show switch circuit on the A500 console.
shows the screen output.
A500:show switch circuit
_______________________________________________________
| Input | Output | Connection |
| port vpi vci| port vpi vci| type class parameters |
|______________|______________|_________________________|
A1.1 0 5 Self 0 1 pp UBR ppd on
A1.1 0 32 A1.2 0 32 pp VBRnrt pcr=5729 /scr=5729 /mbs=17187
A1.1 0 35 A1.2 0 35 pmp CBR pcr=173
A1.2 0 5 Self 0 2 pp UBR ppd on
A1.2 0 32 A1.1 0 32 pp VBRnrt pcr=5729 /scr=5729 /mbs=17187
A1.2 0 34 A1.1 0 34 pmp CBR pcr=173
Self 0 1 A1.1 0 5 pp UBR ppd on
Self 0 2 A1.2 0 5 pp UBR ppd on
_________________________________________________________
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...