![Avaya S8700 Series Скачать руководство пользователя страница 1862](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021862.webp)
Maintenance-Object Repair Procedures
555-233-143
8-1140
Issue 1 May 2002
Modem Pool Conference Test (#97)
This test is destructive.
The Modem Pool Conference test checks most of the switching and gain control
functions provided by the NPE circuit in the analog section of the conversion
resource. This test conferences a 1004-Hz tone through the NPE, looping it back
so that it can be verified with a Tone Detector circuit
Table 8-468.
Test #97 Modem Pool Conference Test
Error
Code
Test
Result
Description / Recommendation
ABORT
System resources required for this test are not available.
1000
ABORT
System resources required to run this test are not available. The port may be
in use on a valid call. Determine whether the port is available for testing.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
1004
ABORT
The port has been seized by a user for a valid call. Determine whether the port
is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1020
ABORT
The test did not run due to a previously existing error on the specific port or
because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit
pack, and attempt to diagnose previously existing errors.
2000
ABORT
The response to the test was not received in the allowable time period.
2012
ABORT
Internal system error.
2100
ABORT
System resources required for this test are not available.
2103
ABORT
The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...