Maintenance-Object Repair Procedures
555-233-143
8-1014
Issue 1 May 2002
LIC-ERR (License-Error Mode)
The LIC-ERR MO works in with the NO-LIC MO to look for any errors/violations
associated with a License file. Once a License file error occurs, LIC-ERR MO
logs the error, raises an alarm, and starts a timer that is associated with the error.
When the timer’s threshold has been exceeded, NO-LIC MO will cause Avaya
MultiVantage ™ to be restricted. All call origination will be restricted to outgoing
emergency numbers, incoming calls will be restricted to an Administration
(Attendant Console) number.
The license file is loaded onto a switch during initialization of the switch software,
restoration of translations, and periodically. After initialization, a query is made to
a software module called the License Server. This module:
■
Reads the serial number in a License file
■
Compares this file’s serial number to a serial number in hardware
■
Compares the file’s serial number with a running software version
and (if a match occurs) delivers permission to run to the MultiVantage software,
along with a new feature mask. The feature mask controls revenue-associated
options.
Error Log Entries and Test to Clear Values
MO’s Name
(in Alarm Log)
Alarm Level
Initial SAT Command to
Run
Full Name of MO
LIC-ERR
MAJOR
test license
License-Error Mode
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
1 (a)
MAJOR
OFF
See footnote
1
1.
These error types can be cleared by providing the correct License file, per local instructions.
513 (b)
None
MAJOR
OFF
See footnote
1
769 (c)
None
MAJOR
OFF
See footnote
1
1281 (d)
None
MAJOR
OFF
See footnote
1
1537 (e)
None
MAJOR
OFF
See footnote
1
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...