Maintenance-Object Repair Procedures
555-233-143
8-1540
Issue 1 May 2002
Procedures for Restoring the System Printer Link
1. Determine the status of the System Printer Link via the status sp-link
command. Verify that the System Printer Link is not busied out for
maintenance. This is indicated by a
no
in the
Maintenance Busy?
field.
If the System Printer Link has been busied out, issue the release sp-link
command. If the link is
down
, proceed to Step 2.
2. Issue the display system feature command to determine the location of
the System Printer Link.
Enter the status data-module extension command and verify that the
data extension is in-service/idle. If the data extension is not available, refer
to the
Port
field. Look for errors and/or alarms on the circuit pack with
which this extension is associated. Follow repair instructions for the
appropriate MO. Continue with Step 3.
3. Verify the availability of the external SYS-PRNT output device. Make sure
that the output device is on-line and ready-for-service. Check the physical
connectivity between the Data Module and the SYS-PRNT output device.
4. Verify that there is at least one C-LAN port available. The System Printer
Link cannot be established without an available C-LAN port. For more
information about C-LAN ports, see
‘‘CLAN-BD (Control LAN Circuit Pack)’’
5. If the problem is not found in the previous steps, check the C-LAN port for
any problems. For a description about C-LAN board and its connectivity,
see
‘‘CLAN-BD (Control LAN Circuit Pack)’’ on page 8-411
It should be noted that when restoring the System Printer link it is necessary to
execute tests on different MOs that comprise the System Printer link. It is
recommended that you busyout the System Printer link before trying to restore the
link. When the System Printer Link is busied out, every System Printer Link
maintenance action is deactivated, and interference with tests of other MOs is
prevented.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...