set options
Issue 1 May 2002
7-277
555-233-143
■
Yes
Alarms are raised in the normal manner. There is no filtering of alarm data.
■
No
Alarms raised on a trunk, station, or adjunct in this category are dropped.
Error information is provided as before, but there is no trace of an alarm.
There is no LED activity and no call to INADS. Because resources are
taken out-of-service without any record, this option is recommended only
when other options do not provide the desired result.
The alarm options can be administered only on a system-wide basis for the
following alarm categories:
■
Major on-board station alarms
■
Minor on-board station alarms
■
Major off-board station alarms
■
Minor off-board station alarms
Four alarm severity groups are provided for trunk alarms. You can administer the
alarm options for the categories listed below in each alarm severity group.
However, in G1, the alarm options can be administered only on a system-wide
basis for the following categories:
■
Major on-board trunk alarms
■
Minor on-board trunk alarms
■
Major off-board trunk alarms
■
Minor off-board trunk alarms
For Adjuncts, an alarm severity option is assigned to each of the following
categories:
■
Major on-board adjunct alarms
■
Major off-board adjunct alarms
■
Minor on-board adjunct alarms
■
Minor off-board adjunct alarms
You can also administer the options on a system-wide basis for minor off-board
DS1 Interface circuit pack alarms.
Alarm reporting options information in the Alarm Reporting Options Form is
considered translation data and, thus, is preserved through every level of restart.
This feature affects the alarming of the MOs listed below. Neither the trunk nor
the station category applies to alarms raised on the common portion of the circuit
pack.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...