Maintenance-Object Repair Procedures
555-233-143
8-470
Issue 1 May 2002
Port Audit Update Test (#36)
This test will send updates of the CO port translation for every port on the circuit
pack that has been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No response
message is expected from the circuit pack once it receives translation updates.
The port translation data includes: ground or loop start trunk, tone or rotary dialing
trunk, rotary dialing inter-digit timing, network balance R/RC, and disconnect
timing.
7,
129,
131,
or
133
FAIL
NOTE:
If the Looparound and Conference Circuit test (#33) fails for every port
on a circuit pack, a -5 Volt power problem is indicated. To investigate
problems with a power unit, see
‘‘CARR-POW (Carrier Power Supply)’’
If a red LED is lit on the TN736 or TN752 power unit circuit pack, replace
the pack. If the test fails on more than 1 port, check for errors on the
TONE-BD or the TONE-PT. If errors, take appropriate actions. When
the tone errors are cleared, rerun the test. If the test fails again, see
‘‘Fault Isolation Using Duplicated PNC’’ on page 8-1294
.
PASS
CO Trunk Looparound and Conference test is successful. User-reported
troubles on this port should be investigated by using other port tests and by
examining trunk or external wiring.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the board, if
necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 8-188.
Test #33 Looparound and Conference Circuit Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...