ANN-BD (Announcement Circuit Pack)
Issue 1 May 2002
8-133
555-233-143
2007
ABORT
The Announcement circuit pack thinks that Port 1 or Port 9 is busy.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, follow the Announcement port maintenance
procedures for Ports 1 and 9.
2100
ABORT
Could not allocate the necessary system resources to run this test.
ABORT
Internal system error. Retry the command at 1-minute intervals up to 5 times.
1–3
FAIL
Test failed. The error code indicates at which speech compression rate the test
actually failed (1 being the first rate tested, 3 being the last).
1. Reset the circuit pack using the reset board UUCSS command and then
run this test again. If the test continues to fail, replace the circuit pack.
2. If there are recurring alarms on this circuit pack caused by this test failing,
replace the circuit pack even if step 1 works.
!
CAUTION:
Replacing the circuit pack causes a loss of integrated announcements.
See
‘‘Essential Service Information’’ on page 8-120
of AN-LN-PT MO.
PASS
The record channel on the announcement circuit pack is functioning properly.
User-reported troubles on this circuit pack should be investigated using other
circuit pack and port tests. Refer to “ANN-PT” for a description of the port tests.
Table 8-49.
Test #210 140AY Loop-Around Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...