Maintenance-Object Repair Procedures
555-233-143
8-328
Issue 1 May 2002
Table 8-141.
Test #595 LANBIC Receive Parity Error
Counter Test
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Response to the test was not received from the circuit pack within the allowable
time period.
1. If the test aborts repeatedly up to five times, reset the circuit pack via the
busyout board UUCSS and reset board UUCSS commands.
2. If the test aborts again, replace the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, escalate the problem.
1–10
FAIL
The circuit pack is still detecting errors of this type. The error code indicates
the value of the on-board error counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, verify the validity of the packet bus. Run the
Packet Bus Maintenance test with the test pkt P long command. If any
packet-bus tests fail, see
‘‘PKT-BUS (Packet Bus)’’ on page 8-1230
for
recommended repair procedures.
3. If the Packet Bus test passes, check the validity of the circuit pack.
Execute a test that involves data transmission onto the packet bus. For
example, the BRI may use the connectivity tests of the port-level MO
(BRI-PORT) by executing the test port UUCSSpp command. Refer to the
repair procedures for the executed test if it fails. Otherwise, proceed to the
next step.
4. Other circuit packs on the packet bus can cause of the parity error. Use
the display errors command to check the Error Log for other circuit packs
that are alarmed. If any alarms are present for the other circuit packs,
retire those alarms also. Then, rerun the LANBIC Receive Parity Error
Counter test (#595) on this circuit pack.
PASS
No errors detected by circuit pack.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...