![Avaya S8700 Series Скачать руководство пользователя страница 2167](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022167.webp)
SNI-BD (SNI Circuit Pack)
Issue 1 May 2002
8-1445
555-233-143
103
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 3 over the circuit
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 3. Use
display errors to find any SNI-BD errors and check display alarms to see
whether the errors have on-board alarms. Then follow the associated
repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 257. If other SNI circuit packs have SNI-PEER error
type 257, then replace the SNI in slot 3. Replacing an SNI may be service
interrupting. See
‘‘SNI-BD (SNI Circuit Pack)’’ on page 8-1429
for the
procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 257 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 3.
104
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 4 over the circuit
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 4. Use
display errors to find any SNI-BD errors and check display alarms to see
whether the errors have on-board alarms. Then follow the associated
repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 513. If other SNI circuit packs have SNI-PEER error
type 513, then replace the SNI in slot 4. Replacing an SNI may be service
interrupting. See
‘‘SNI-BD (SNI Circuit Pack)’’ on page 8-1429
for the
procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 513 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 4.
Table 8-576.
TEST #755 SNI Circuit Path Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...