Figure 4-27.
A500: show stats sonet a1.2 screen
2. Ensure that the fields have the following indicated values.
Receive
Cell Count
Each field’s values should be increasing if the TN230X is
actively sending and receiving cells with the A500. (Even if
a TN230X did not achieve board insertion, it will still try to
talk to the A500.)
Transmit
Cell Count
If neither field is increasing, the A500 port may have been
marked down using the admin down command. Use the
show system interfaces command to verify that the
Admin Status
is up.
If the
Receive Cell Count
is increasing but the
Transmit Cell Count
is not increasing, this may be
because the port was administered with no UNI signaling
(admin link command). Use the show signaling summary
command to ensure that
Signaling
is
UNI3.1
.
The error counters may not be zero, but should not be large
either compared to the receive and transmit cell counters. If
the counters are large and increasing, check the fiber
integrity. Make sure the fiber pairs are securely plugged into
both the TN230X and the A500.
If the fiber has been pulled and reinserted as part of fault
diagnosis, the non-zero
Loss of Signal Err
counter
may be correct.
Sonet per-Port Statistics
---------------------------------
Receive Cell Count: 80654
Transmit Cell Count: 79555
Section Level Bit Err: 1
Line Bit Err: 1
Line FEB Err: 168
Path Bit Err: 1
Path FEB Err: 98
Correctable HCS Err: 0
Uncorrectable HCS Err: 0
Loss of Frame Err: 1
Loss of Signal Err: 0
Out of Frame Err: 0
Path Signal Label: 19
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...