PKT-BUS (Packet Bus)
Issue 1 May 2002
8-1233
555-233-143
d. The Maintenance/Test packet bus port (M/T-PKT) has detected a Packet
Bus fault and has taken corrective action by swapping to spare leads. This
error appears only in high/critical-reliability systems (duplicated PNC). The
Aux Data value indicates the number of faulty leads. If this is the only
active error against the packet bus, the packet bus is still in service. Due to
the disruptive nature of the packet bus Fault Isolation and Correction
procedures, repairs should be deferred until a time when the least
interruption in service would result. This should be determined by
consultation with the customer. However, do not delay repairs for too long,
since the switch cannot recover from another packet bus failure until the
current one is resolved.
‘‘Isolating and Repairing Packet-Bus Faults’’ on
Chapter 4, ‘‘Alarms, Errors, and Troubleshooting’’
contains a
sub-section, A Special Precaution Concerning the TN771D that describes
how to ensure that the TN771D is providing correct information. A new
TN771D may need to be taken to the customer site.
e. The Maintenance/Test packet bus port (M/T-PKT) has detected open leads
on the packet bus. The Aux Data value indicates the number of open
leads.
f. Packet circuit pack, port, and endpoint maintenance has been disabled due
to a packet bus failure. The Aux Data value indicates the cause:
Keep in mind that although only packet circuit packs can detect and report
packet bus problems, such problems can be caused by any circuit pack.
g. Packet circuit pack, port, and endpoint maintenance has been disabled due
to more than one circuit pack reporting in-line errors. If this occurs more
than three times in 15 minutes a Minor alarm is raised against the packet
bus. This happens when maintenance is disabled due to errors and is then
re-enabled because no more errors are reported.
This error may still be present in the error log even though the Packet
Circuit Pack Audit test (#573) indicates that only one circuit pack is
reporting a problem. This happens when more than one circuit pack has
reported errors in any 1-minute interval since the packet bus fault occurred.
Aux
Data
Cause
1
In-line errors from packet circuit packs
2
Uncorrectable packet bus fault reported by the
Maintenance/Test packet bus port (M/T-PKT)
3
Both of the above
100x
Packet-related circuit pack, port, and endpoint
maintenance in the PN has been disabled due to a packet
bus failure in the PN. The last digit has the same meaning
as the single digits listed above.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...