AN-LN-PT (Analog Line Port)
Issue 1 May 2002
8-101
555-233-143
AN-LN-PT (Analog Line Port)
The TN793B/TN2793B Analog Line (w/ Caller ID) and the TN797 Analog Trunk
and Line circuit packs both support this MO.
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID) provides 24 ports
for voice terminals and supports both on-premises and off-premises analog voice
terminals.
The TN797 Analog Trunk and Line circuit pack provides 8 ports, each of which
may be administered in any of several ways, as described in MO TR-LN-BD.
NOTE:
The TN793B/TN2793B analog line circuit pack supports analog data
modules. When assigned, analog data modules provide access to the
NetPkt (TN794 circuit pack) data ports. To activate an analog data module
you must assign the port location on the data form and connect a modem to
the port. The analog data module can be used for connection to a CDR
output, or other adjuncts as needed. These ports are tested like any other
analog port on the circuit pack.
Ringing caused by maintenance testing
Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing disturbs the customer or the terminal equipment,
disable it in the
Tests
field of the change station extension form. Be aware that
this action also disables Tests #6, 7, 161, and 35 on some software releases.
MO’s Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
pp is the 2-digit port number (01, 02, 03 ...).
Full Name of MO
AN-LN-PT
MINOR
test port UUCSSpp l
Analog Line port
AN-LN-PT
WARNING
test port UUCSSpp sh
Analog Line port
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...