![Avaya S8700 Series Скачать руководство пользователя страница 930](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102930.webp)
Maintenance-Object Repair Procedures
555-233-143
8-208
Issue 1 May 2002
1414
ABORT
The active Tone-Clock circuit in one of the EPNs being used for the test has a
MAJOR or MINOR alarm logged against it.
1. Enter display alarms and resolve any TONE-BD and TONE-PT alarms.
1956
ABORT
ACL to the board is not up. See ACL status with the list sys-link command
and follow the repair procedures for SYS-LINK.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
The test tone was not detected correctly in either direction.
1. Test the active Tone-Clocks in the EPNs for which the ATM-EI circuit pack
under test provides a link. This determines if the dial tone is supplied.
10MM
FAIL
The failure codes only apply to a system equipped with an ATM Switch. The
letters “MM” refer to the distant or far-end EPN, and “NN” to the near-end
ATM-EI under test.
The test tone was detected correctly in forward direction (data sent from the
EPN where the circuit pack under test resides and detected correctly in port
network MM), but not the opposite direction.
1. Test the active Tone-Clocks on the “MM” EPN and the EPN where the
ATM-EI under test resides (test tone-clock UUCSS). This determines if a
dial tone is supplied.
2. Ensure that the ATM address of the ATM-EI circuit pack under test
matches the ATM address on the ATM switch for the port to which this
circuit pack is connected. Refer to ATM Installation, Upgrades, and
Administration for Avaya MultiVantage Solutions book for the procedure to
check the ATM port address on the ATM switch.
3. Run Test #241 on the active ATM-EI in port network MM. If this test fails
with Error Code 10NN or 30NN, go back to step 2.
4. If the address was the same, replace the active ATM-EI circuit pack on port
network MM.
5. If this test fails with Error Code 20NN or 40NN, replace ATM-EI circuit pack
that had the initial problem.
Table 8-85.
Expansion Interface 2-Way Transmission Test (#241) —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...