![Avaya S8700 Series Скачать руководство пользователя страница 2221](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022221.webp)
STRAT-3 (Stratum-3 Clock)
Issue 1 May 2002
8-1499
555-233-143
The output of the CI and PAI cards go directly to the TN780 Tone-Clock circuit
pack via two 25-pair amphenol-terminated cables. Every card has red and/or
green LEDs for providing status or alarm indications. The abbreviations used in
the table are defined above except for SRC (source) and PLL (Phase Locked
Loop).
Table 8-585.
Stratum-3 Clock LED Indications
Card
Name
Color
Indication
PAI
REF A
Red
Loss of input reference A or CI A failed
REF B
Red
Loss of input reference B or CI A failed
ST A
Red
Failed Stratum-3 clock A
ST B
Red
Failed Stratum-3 clock B
PWR A
Green
-48VDC A present
PWR B
Green
-48VDC B present
CI
FAIL
Red
Card failure
DS1
Green
DS1 source present
CC
Green
Composite clock source
1
present
1.
Composite Clock (CC) source refers to the protocol used to electrically transfer timing from the Stratum-3
clock to the switch. The Composite Clock source is not relevant to the system.
SRC ACTIVE
Green
Card is currently on-line
ST3
FAIL
Red
Card failure
LOCK
Red
PLL lost sync with reference or holdover mode
REF A
Red
Timing Reference from CI A
REF B
Red
Timing Reference from CI B
TOC
FAIL
Red
Card failure
PORT ALM
Red
Output port alarm (one or more)
ST
Green
Reference present from ST clock
INPUT
Green
Reference present from CI
500’
Green
500-foot phase advance
1000’
Green
1000-foot phase advance
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...