Maintenance-Object Repair Procedures
555-233-143
8-1372
Issue 1 May 2002
Speech Synthesis Memory Test (#166)
The encoded speech for the Speech Synthesis circuit pack is stored in on-board
read-only memory (ROM). A checksum is computed for each 32K speech
memory block and compared against a known checksum value. If every
computed checksum value is successfully compared against the stored checksum
values, the test passes. If, while testing the speech complex memory, the
on-board microprocessor finds a memory error, the test is terminated and a failure
is reported. This type of failure may affect other ports on the Speech Synthesis
circuit pack, resulting in errors or alarms on each port.
Table 8-561.
TEST #166 Speech Synthesis Memory Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call and therefore unavailable for certain tests. Wait until the
port is idle (amber LED is off) before retesting.
1. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1019
ABORT
Test is already running on a different port, possibly due to background
maintenance activity. Only one of these tests may be active on a circuit pack at
a time.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The computed checksum from the speech vocabulary ROM did not compare
correctly with the stored checksum. This type of failure may cause features
using the Speech Synthesis port’s speech services to malfunction and result in
degradation of synthesized speech quality ranging from insignificant to major.
1. Replace the circuit pack.
PASS
The computed checksum values were successfully compared against the
stored checksum values. User-reported troubles should be investigated using
other tests and by verifying other ports on this circuit pack are working
correctly.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...