TONE-BD (Tone-Clock Circuit)
Issue 1 May 2002
8-1679
555-233-143
Notes:
a. See
‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872
descriptions of these tests.
b. See
‘‘TONE-PT (Tone Generator)’’ on page 8-1682
for descriptions of
these tests.
c. See
‘‘TDM-CLK (TDM Bus Clock)’’ on page 8-1604
for descriptions of
these tests.
d. This test runs only on the standby IPSI or Tone-Clock circuit in a port
network with duplicated Tone-Clocks (high- or critical-reliability systems).
The circuit pack must be a TN780 with firmware version 2 or above.
e. See
‘‘ETR-PT (Enhanced Tone Receiver Port)’’ on page 8-755
descriptions of these tests.
Clock Health Inquiry Test (#46)
This inquiry reads special data stored in memory to determine if this IPSI or
Tone-Clock circuit pack had a loss of any of three clock types:
■
SYSCLK
■
SYSFM
■
SYSDCLK
If this data indicates this IPSI or Tone-Clock circuit pack had a loss of any of these
clocks, the inquiry reports FAIL. In addition, if TDM-CLK error 1 is at threshold,
this test will FAIL. TDM-CLK error 1 indicates a suspect clock is at the edge of its
specified frequency. If the circuit pack did not have a loss of clock or TDM-CLK
error 1 at threshold, the inquiry reports PASS.
This is not really a test, in the sense that it simply reports status held by the
system, and does not generate new information or raise alarms. If this test fails
with no error code, there is at least one Major alarm against an IPSI or Tone-Clock
circuit pack. If this test fails with an error code of 1, there is at least one Minor
off-board alarm against a TDM-CLK.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...