AN-LN-PT (Analog Line Port)
Issue 1 May 2002
8-109
555-233-143
Battery Feed Test (or Port Diagnostic Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery power, and detecting the resulting current.
Table 8-42.
Test #35 Battery Feed Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Necessary system resources could not be allocated to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources are unavailable. The port may be busy with a valid call.
This result is also reported for the system’s Music-On-Hold port when it is
off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the station’s extension.
2. Enter status station extension to determine the service state of the port.
3. If the port is active, wait until it is idle. Retry the command at 1-minute
intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1004
ABORT
A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station extension command to determine the service
state of the port.
3. If the port is active, wait until it is idle before testing. Retry the command at
1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005
ABORT
This test was aborted due to a configuration problem. The test is not applicable
for this type of analog port. This error can be ignored.
1018
ABORT
Administration has disabled the test. The default for the
Test?
field on the
station form is y. Determine why this field has been set to n on this station (this
may be due to the ringing application Test #48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station extension.
2. Change the
Test?
field on the station form to y.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...