Maintenance-Object Repair Procedures
555-233-143
8-30
Issue 1 May 2002
1000
ABORT
System resources required to run this test are not available. The port may be
active.
1. Use the display port UUCSSpp command to determine the voice port
extension of the port. Use the status station command to determine the
service state of the port. If the port is active, it is unavailable for certain
tests. Refer to “Status” commands in
, for a full description of every possible state. Wait until the
port is idle before testing.
2. If the port’s status is idle, retry the command at 1-minute intervals up to 5
times.
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
1004
ABORT
The port was put in use during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the voice port
extension of the port. Use the status station command to determine the
service state of the port. If the port is active, it is unavailable for certain
tests. Refer to “Status” commands in
for explanations of every possible state. Wait until the port is
idle before testing.
1020
ABORT
Test disabled via background testing. Use the status station command to
determine when the voice port is available for testing.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
1, 2
FAIL
The NPE of the tested port was found to be transmitting in error. This causes
noisy and unreliable connections. Failure code 1 indicates that the Crosstalk
test failed on the primary channel. Failure code 2 indicates that the Crosstalk
test failed on the secondary channel.
1. Replace the circuit pack (see caution at the beginning of this section).
Table 8-10.
Test #9 NPE Crosstalk Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...