Maintenance-Object Repair Procedures
555-233-143
8-152
Issue 1 May 2002
63
Service or
option not
available
Requested ASAI capability or resource is not available on the switch or
adjunct. More than one adjunct may be contending for the same switch
resource. Potential administration mismatch between the resource
domains administered on the switch and those administered on the
adjunct.
1. Verify that no overlapping administration of switch resources (for
example, requesting notifications on a single domain by multiple
adjuncts attempting to control a single call) exists across any
adjunct connected to the switch. If an overlap exists, then
re-administer the adjuncts to ensure that each adjunct is associated
with a unique set of switch resources.
65
Bearer service
not
implemented
Requested service not implemented in switch or endpoint.
69
Requested
facility not
implemented
Requested service not supported in switch or endpoint.
1. Consult switch and endpoint documentation to determine service
support.
79
Service or
option not
implemented
Requested service or option (or combination of selected options) is not
supported (implemented) in switch or the adjunct.
1. Consult switch and adjunct documentation to determine ASAI
service and options supported by both switch and adjunct.
Re-administration of the switch-administered capabilities (see
Customer Optional Feature form) or those of the adjunct may be
necessary to correct the problem.
81
Invalid CRV
An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between the switch and the
adjunct. See the CallVisor protocol reference manual.
87
Internal switch
audit
There is an inconsistency in switch data records.
1. There is no action needed, since the switch has corrected the data
inconsistency.
Table 8-57.
ASAI Cause Values —
Continued
Code
Explanation
Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...