Maintenance-Object Repair Procedures
555-233-143
8-228
Issue 1 May 2002
1962
ABORT
Every DSPs is busy (an unlikely event).
1. Retry the command at 1-minute intervals up to 3 times.
2000
ABORT
Response to the test was not received within the allowable time period for
some of the DSPs.
1. If the board is in standby, reset the board and run the test again.
2. Look into the Error Log for Error Type 1218 (bad DSP). If Error Type 1218
is not logged against this board, run the DSP test again and see if the error
persists.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2302
ABORT
Inconsistent uplink message from the ATM-EI board (an unlikely event).
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABORT
Internal system error
2752
ABORT
The circuit pack in this location is not a TN230X.
XYZ
FAIL
A device on the circuit pack is failing. There is at least one bad DSP on the
board. Values are as follows:
■
The X value indicates the number of talker DSPs
■
Y indicates the number of listener DSPs
■
Z indicates the number of Echo Canceler DSPs that have failed the test.
1. Run the tests for the active Tone-Clock on the EPN that contains the
indicted ATM-EI circuit pack to verify that dial-tone is supplied.
2. If the Tone-Clock is healthy, repeat the short test on the ATM-EI board.
3. If this test continues to fail, replace the ATM-EI circuit pack.
XYZ
PASS
The test passed for some or all DSPs depending on XYZ values. XYZ
indicates the number of talker, listener and echo-canceler DSPs for which the
test passed, respectively. In the DSPs that passed the test, the test tone was
correctly detected by the DSP Listener and by tone-detector for the DSP
Talkers on both buses, and the Echo Canceler DSPs are working properly.
0
NO
BOARD
No board was detected by the test.
1. Check the Error Log for wrong board (Error Type 125) or no board (Error
Type 131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (Error Type 1538). If hyperactive, use the reset board
UUCSS command.
3. Run the test again. If it fails, the circuit pack could be bad. Replace the
circuit pack and retest.
Table 8-95.
ATM Board DSP Test (#1293) —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...