![Avaya S8700 Series Скачать руководство пользователя страница 402](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102402.webp)
Maintenance Commands
555-233-143
7-146
Issue 1 May 2002
Scheduled Maintenance
A series of maintenance tests and operations runs automatically every day
according to the schedule and settings specified in the following fields.
Start Time
The hour and minute in 24-hour notation at which daily scheduled
maintenance will begin running. (22:00)
Stop Time
The hour and minute when scheduled daily maintenance will stop running.
If any daily maintenance operations are not completed by this time, the
system will note where in the sequence it stopped and perform those
operations during the next scheduled daily maintenance.
Save
Translation
This field indicates on which days translation data in memory will
automatically be saved to the hard disk during scheduled maintenance.
The save operation is first made to disk, followed by a disk backup. Valid
entries are daily, days of the week, or no. “No” specifies that no automatic
saves are to be executed. (daily)
Control
Channel
Interchange
Each port network has a pair of TDM busses called A and B, each of which
has a set of time slots dedicated to use by the control channel. At any one
time, the control channel in each PN is carried on only one of the two
busses. This field indicates on which days the control channel in each port
network will be switched from one of the paired TDM busses to the other.
Valid entries are daily, days of the week, or no. “No” specifies that no
interchange be executed. (no)
display system-parameters maintenance Page 3 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
MAINTENANCE SAVE TRANSLATION CORRUPTION AUDIT
Enable Translation Audit? y
Display Warning When Detected? n
Alarm When Detected? n
Block Save Translation When Detected? n
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...