Maintenance Commands
555-233-143
7-266
Issue 1 May 2002
reset system
reset system [level#]
!
CAUTION:
All system resets are service affecting, with higher levels being increasingly
destructive. Some resets may take up to one half hour to complete. Certain
conditions may result in a higher reset level than the one requested. Unless
you are experienced with resetting a system, follow normal escalation
procedures.
This command causes the Avaya Call Processing (ACP) application to be
reloaded. All system resets (except reset system interchange) are disruptive and
terminate the G3-MT login.
System software will generally not escalate a demand system reset to a higher
level. There are certain conditions that result in a higher level reset than that
requested. These include the following:
■
A PNC interchange is already in progress.
■
A change in translation administration is in progress.
Parameters
Examples
reset system 1
Output
Once this command is entered, it may not be canceled. The screen will display
the results of various initialization tests. If the reset command is successful the
user will be logged off. Several conditions may prevent a requested reset.
Level
Reset levels are numbered as shown in
. The execution times listed are
approximations.
Table 7-41.
Approximate Recovery Time for System Resets (min:sec)
Level
Recovery
2,400 lines
5,000 lines
15,000 lines
Disk
Disk
Disk
1
Warm Restart
:10
:10
:10
2
Cold-2
1:00
2:00
4:00
4
Reload
4:00
6:30
11:00
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...