Maintenance-Object Repair Procedures
555-233-143
8-1674
Issue 1 May 2002
2. If the error is not corrected by resolving errors found in step 1, the
IPSI or Tone-Clock circuit pack should be replaced. See
the IPSI or Tone-Clock Circuit Pack’’
NOTE:
Replacing the circuit pack and retesting it with the test
tone-clock command is not adequate to retire this alarm and
return the IPSI or Tone-Clock circuit pack to full service; the
Clock Health Inquiry test (#46) will continue to fail. Because
the ability to generate clocks was considered lost, once any
repairs have been made it is necessary to execute the set
tone-clock PC override command, forcing the circuit pack to
become active. If the problem has not actually been
corrected, this action may cause a disruption in service for
active digital facilities users.
3. If error 2305 or 3848 persists, all clock signals from the indicated
board were lost.
If the reported Tone-Clock circuit is in a port network with duplicated
Tone-Clocks, the problem may lie with the circuit pack responsible
for selecting the active Tone-Clock circuit (the t/c selector). For an
EPN, the t/c selector is the active EXP-INTF circuit pack.
The t/c selector circuit pack of interest is the one which was active at
the time the error was logged. This is the currently active t/c
selector, unless there has been an EXP-INTF link switch for an EPN
problem. In order to determine whether an interchange has
occurred since the TONE-BD error, examine the display initcauses
log for EXP-LNK entries in the hardware error log for expansion link
interchanges.
If the t/c selector circuit pack was not replaced as part of the
previous step, replace it now. Follow procedures described in
‘‘EXP-INTF (Expansion Interface Circuit Pack)’’ on page 8-762
the Expansion Interface.
4. If the error has not been corrected at this point, there is a problem
with the TDM bus within the port network containing the reported
Tone-Clock circuit. This may include TDM bus intercarrier cables,
bus terminators, bent pins on the backplane, and errors on any
circuit pack plugged into the same port network. See
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...